Plan Vent System
Choose your exhaust installation type
Recommended
exhaust installation:
py
O
eee
i
Standard rear exhaust installation
Optional exhaust installations:
Gh)
é
Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit.
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
Exhaust can be converted out the right side, left side, or through
the bottom (4-way vent kit, part number W10337804).
Each kit
includes step-by-step instructions.
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Fo
O
bh
=i
Bottom exhaust installation
Determine vent path:
@ Select route that will provide straightest and most direct
path outdoors.
@ Plan installation to use fewest number of elbows and turns.
@ When using elbows or making turns, allow as much room
as possible.
@ Bend vent gradually to avoid kinking.
@ Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
@ Use following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent system chart.
Exhaust systems longer than those specified will:
@ Shorten life of dryer.
@ Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent system chart provides venting requirements that will
help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90° turn
inside the dryer. To determine maximum exhaust length, add
a 90° turn to the total number of elbows when referemcing
the chart.
(~
Vent system chart
Number of
Type
Box/louvered
Angled
90° elbows
of vent
hoods
hoods
0
Rigid metal |
64 ft. (20m) | 58 ft. (17.7 m)
1
Rigid metal | 54 ft. (16.5 m) | 48 ft. (14.6 m)
2
Rigid metal | 44 ft. (13.4 m) | 38 ft. (11.6 m)
3
Rigid metal | 35 ft. (10.7 m) | 29 ft. (8.8 m)
4
Rigid metal | 27 ft. (8.2 m)
21 ft. (6.4 m)

Publicité