ACTIVATING AND DEACTIVATING RF 3-POSITION SWITCHES:
The switch delivered standard from the factory is linked to the ventilation
unit. A total of up to 20 wireless switches can be linked to the system.
ACTIVATING AND DEACTIVATING RF 3-POSITION SWITCH:
Activation:
Take the ventilation unit plug out of the socket and put it back in again.
The ventilation unit will now search for new switches for 10 minutes.
Press the position 2 button and the timer simultaneously for at least 3
seconds. If the linking action is successful, the LED in the middle lights up
green twice.
Tip: You can link a single switch to a maximum of 3 ventilation units.
Deactivation:
Take the plug out of the socket and put it back in again. The ventilation
unit can unlink switches during 10 minutes. Press the buttons for positions
1 and 3 simultaneously for at least 3 seconds. The LED of the switch lights
up orange twice in order to indicate that the switches have been unlinked.
ACTIVATING AND DEACTIVATING OPTIONAL CO
RF SWITCH:
2
Activation:
Take the ventilation unit plug out of the socket and put it back in again.
The ventilation unit will now search for new switches for 10 minutes. Then
click the sensor on the bottom plate in order to make it go live again.
Touch the control zone at the bottom right for at least 3 seconds. When all
of the LEDs are flickering you must release the control zone. If the linking
action is successful, the LED in the upper left corner lights up green twice
and on the right a LED will light up that indicates in which relevant position
the CO2 RF switch finds itself.
Tip: You can link a single switch to a maximum of 3 ventilation units.
Deactivation:
Kill the switch briefly by clicking it out of and then back into the base plate.
The switch can unlink ventilation units for 10 minutes. Touch the control
zone at the bottom right for at least 10 seconds. When all LEDs light up
green for the 2nd time you must release the control zone. In the event of
several activated ventilation units, all activated ventilation units are
deactivated as a result. The LED of the switch lights up red four times in
order to indicate that the ventilation units are unlinked.
COMMISSIONING AND ADJUSTMENT 23