3. Use an appropriately sized screwdriver
to adjust the flow rate adjustment
screw.
4. For LPG (Butane - Propane) turn the
screw clockwise. For the natural gas,
you should turn the screw counter-
clockwise once.
ð The normal length of a straight
flame in the reduced position
should be 6-7 mm.
5. If the flame is higher than the desired
position, turn the screw clockwise. If it
is smaller turn anticlockwise.
6. For the last control, bring the burner
both to high-flame and reduced posi-
tions and check whether the flame is on
or off.
7. Depending on the type of gas tap used
in your appliance the adjustment screw
position may vary.
Flow rate adjustment screw
1
1
Flow rate adjustment screw
Leakage check at the injectors
Before carrying out the conversion on the
product, ensure all control knobs are turned
to off position. After the correct conversion
of injectors, for each injectors should be
gas leak checked.
1.
Make sure that the gas supply to the
product is on, still maintaining all con-
trol knobs turned to off position.
2.
Each injector hole is blocked with a fin-
ger applying reasonable force to stop
the gas leakage when corresponding
control knob turned to on and it held at
depressed position to allow gas reach
the injector.
3.
Apply prepared soapy water at the in-
jector connection with a small brush, if
there is leakage of gas at the injector
connection the soapy water will begin
to froth. In this case, tighten the in-
jector with a reasonable force and re-
peat step 3 process once again.
4.
If the froth still persist you must turn
off the gas apply to the product imme-
diately and call an Authorised service
agent or technician with licence. Do not
use the product until the authorized
service has intervened in the product.