Télécharger Imprimer la page

Beko HILG 64120 S Manuel D'utilisation page 23

Publicité

• The convertible gas type and gas cat-
egories of your product by country are
given in the "Country gas categories/
types/pressure" section. Check the table
in this table for the types of gas you can
convert in your local area. You cannot
convert to unspecified gas types in this
table.
• Spare injector suitable for the type of gas
you wish to convert may not be supplied
with product. You can obtain the inject-
ors from the authorized service or from
the place where you purchased the
product.
• Injector values and gas types that should
be used for burners are given at the end
of the section. Make the connection of
the gas type to be converted as de-
scribed in the gas connection section.
Parts for Gas Conversion
The parts and tools visuals, may be re-
quired for the gas conversion are given be-
low. Depending on the model, these parts
may not be given with the product.
Bypass nozzle:
Burner injector:
Exchange of injector for the burners
1. Turn all control knobs to off positions
on the control panel.
2. Shut off the gas supply.
3. Remove the pan supports, the cap and
head of the hob burners.
4. Remove the gas injectors by turning
counter clockwise. (spanner 7)
5. If your product has a wok combustor
with a side-entry injector, remove the in-
jector with a number 7 spanner.
On some hob burners, the injector
is covered with a metal piece. This
metal cover must be removed for
injector replacement.
6. Install the new gas injectors. (Tightening
torque 4 Nm)
7. Check all connections in order to make
sure that they are installed safely and
securely.
New injectors have their position
marked on their packing or injector
table on can be referred to.
8. You must check for leakage injectors
after connection.
Unless there is an abnormal condi-
tion, do not attempt to remove the
gas burner taps. You must call an
Authorised service agent or techni-
cian with licence if it is necessary
to change the taps.
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjusted
and turn the knob to the reduced posi-
tion.
2. Remove the knob from the gas tap.