Gas outlet connection piece :
Making the gas connection - NG
• Natural gas installation must be prepared
suitably for the assembly before in-
stalling the product. There must be a nat-
ural gas valve at the outlet of gas system
to be connected to the product.
• Make sure that the natural gas valve is
readily accessible.
• Connect your product to the natural gas
system in your home with a flexible gas
hose that complies with local standards.
• A new sealing gasket must be used while
making the gas connection.
• The gas supply must be connected via a
gas pipe or a safety gas hose with
threaded fittings at both ends.
EN ISO 228 G1/2" type connection
1. Insert the new sealing gasket into the
safety gas hose/pipe. Make sure the
gasket is seated correctly.
2. Secure the gas connection piece to the
appliance with using a 22 mm spanner
and place the connection piece into the
connection piece using a 24 mm span-
ner.
3. You must check for leakage of the con-
nection part after connection.
EN 10226 R1/2" type connection
1. Place the new seal in the connection
piece and make sure the seal is seated
correctly.
2. While holding the gas connection outlet
of the product fixed with a 22 spanner,
connect the interconnection piece to the
product gas outlet with a 24 spanner
and tighten securely.
3. Insert the new sealing gasket into the
safety gas hose/pipe. Make sure the
gasket is seated correctly.
4. Connect the threaded part of the safety
gas hose/pipe to the interconnector
with the 24 mm spanner and tighten se-
curely, holding the interconnector in
place with the 24 mm spanner.
5. You must check for leakage of the con-
nection part after connection.
Making the gas connection - LPG
• Your product should be connected in a
way that it will be close to the gas con-
nection to prevent gas leakage.
• Before making your gas connection,
provide a plastic gas hose and suitable
mounting clamp. The inner diameter of
the plastic gas hose must be 10 mm and
the length should not be longer than 150
cm. The plastic hose must be leak-proof
and inspectable.
• Gas appliances and systems must be
regularly checked for proper functioning.
Regulator, hose and its clamp must be
checked regularly and replaced within the
periods recommended by its manufac-
turer or when necessary.
• A new sealing gasket must be used while
making the gas connection.
EN / 20
EN
PL
FR