Lubrication
1. Be sure to use JUKI genuine oil and JUKI genuine grease to the parts to be lubricated.
2. If the oil adheres on your eye or body, be sure to immediately wash it off in order to prevent infl ammation or irritation.
3. If the oil is swallowed unintentionally, be sure to immediately consult a medical doctor in order to pre-
vent diarrhea or vomiting.
Maintenance
1. In prevention of accident caused by unfamiliarity with the machine, repair and adjustment has to be
carried out by a service technician who is thoroughly familiar with the machine within the scope defi ned
in the instruction manual. Be sure to use JUKI genuine parts when replacing any of the machine parts.
JUKI assumes no responsibility for any accident caused by improper repair or adjustment or the use of
any part other than JUKI genuine one.
2. In prevention of accident caused by unfamiliarity with the machine or electrical-shock accident, be sure
to ask an electrical technician of your company or JUKI or distributor in your area for repair and mainte-
nance (including wiring) of electrical components.
3. When carrying out repair or maintenance of the machine which uses air-driven parts such as an air cyl-
inder, be sure to remove the air supply pipe to expel air remaining in the machine beforehand, in order to
prevent accident caused by abrupt start of the air-driven parts.
4. Be sure to check that screws and nuts are free from looseness after completion of repair, adjustment
and part replacement.
5. Be sure to periodically clean up the machine during its duration of use. Be sure to turn the power off and
verify that the machine and motor stop completely before cleaning the machine in order to prevent ac-
cident caused by abrupt start of the machine or motor.
6. Be sure to turn the power off and verify that the machine and motor stop completely before carrying out
maintenance, inspection or repair of the machine. (For the machine with a clutch motor, the motor will
keep running for a while by inertia even after turning the power off. So, be careful.)
7. If the machine cannot be normally operated after repair or adjustment, immediately stop operation and
contact JUKI or the distributor in your area for repair in order to prevent accident that can result in per-
sonal injury or death.
8. If the fuse has blown, be sure to turn the power off and eliminate the cause of blowing of the fuse and re-
place the blown fuse with a new one in order to prevent accident that can result in personal injury or death.
9. Be sure to periodically clean up the air vent of the fan and inspect the area around the wiring in order to
prevent fi re accident of the motor.

Operating environment

1. Be sure to use the machine under the environment which is not affected by strong noise source (electro-
magnetic waves) such as a high-frequency welder in order to prevent accident caused by malfunction of
the machine.
2. Never operate the machine in any place where the voltage fl uctuates by more than "rated voltage ±10 %"
in order to prevent accident caused by malfunction of the machine.
3. Be sure to verify that the air-driven device such as an air cylinder operates at the specifi ed air pressure
before using it in order to prevent accident caused by malfunction of the machine.
4. To use the machine with safety, be sure to use it under the environment which satisfi es the following conditions:
Ambient temperature during operation
Relative humidity during operation
5. Dew condensation can occur if bringing the machine suddenly from a cold environment to a warm one. So,
be sure to turn the power on after having waited for a suffi cient period of time until there is no sign of wa-
ter droplet in order to prevent accident caused by breakage or malfunction of the electrical components.
6. Be sure to stop operation when lightning fl ashes for the sake of safety and remove the power plug in
order to prevent accident caused by breakage or malfunction of the electrical components.
7. Depending on the radio wave signal condition, the machine may generate noise in the TV or radio. If this
occurs, use the TV or radio with kept well away from the machine.
8. For the worker who is involved in the work to be done in the environment relevant to "noise value in the
working environment is 85 dB or more and less than 90 dB", be sure to take appropriate measures, as
required, such as the use of ear protection or the like to protect against health hazard. In addition, for the
worker who is involved in the work to be done in the environment relevant to "noise level in the working
environment is 90 dB or more," be sure to instruct him/her to wear ear protection without exceptions in
order to protect against health hazard, and display a sign explaining how to use the ear protection at an
easily viewable location for the worker.
9. Properly dispose of packages of the sewing machine and used lubricating oil according to the relevant
national law(s) in your country.
5℃ to 35℃
35 % to 85 %
iv