User guide Autotrol 255 Easy-iQ
4
Programming
4.1
Controller quick start
1. Use
and
to select the submenu.
2. Press
to validate the submenu
selection.
ð The parameters of the selected
submenu are displayed.
3. Use
and
to select the desired
parameter.
4. Press
to validate the parameter
selection.
ð The controller displays the submenu
with the selected parameter.
5. Repeat this procedure for all submenus
(Language, Valve selection, Unit of
measure, Hardness unit, Hardness
setting, Resin amount, Salt dosage, Time,
Date).
6. When setting is done, validate to display
Service menu.
4.2
Diagnostics menu
+
1. Press
to display Diagnostics submenus.
2. Using
and
3. Press
to validate the selection.
4. Using
and
5. Press
to come back to Diagnostics menu.
6. Repeat this procedure from its third point as needed.
5
Operation
5.1
Recommendations
• Use only regeneration salts designed for water softening EN973;
• for optimal system operation, the use of clean salt and impurities free is recommended (for example salt pellets);
• do not use ice melt salt, block, or rock salts;
• the sanitizing process (both with liquid and electrochlorination) may introduce chlorine compounds which may reduce
the life of the ion exchange resins. Refer to media manufacturer specifications sheet for more information.
5.2
Trigger a regeneration
Regeneration options:
• Now (Regeneration starts immediately. Controller goes to regeneration screen);
• Delayed (Controller goes back to service screen. Regeneration starts on the scheduled time);
• Cancel (No regeneration and controller goes back to service screen).
8 / 48
, scroll between the different submenus to select the one to consult.
, scroll to consult the different submenu information.
Language
English
Valve Selection
255 (Actual setting - before)
268 (New setting - after)
Unit Of Measure
mg/L or PPM
Valve Selection
255 (Actual setting)
Valve Selection
263
Valve Selection
268 (Desired option)
Valve Selection
269