TECNO-GAZ
2. INSTALLATION
2.1 Positioning the machine
All the packaging materials can be recycled.
•
Open the packaging carefully.
•
Do not overturn the machine as this may cause irreparable damage.
•
Cut the strap or open the box and remove the expanded polystyrene corner guards.
•
Remove the box followed by the nylon bag.
•
Caution: the bag represents a serious hazard for children and should be disposed of immediately.
•
Place the machine on the work surface and level it by adjusting the feet.
2.2 Water connection (for the installer only)
•
This machine should be connected to the water network in compliance with current legislation
•
The non-return system for water is already in place inside the machine.
•
Connect using cocks with ¾" couplings in an easily accessible position.
•
Make sure that the mains water pressure falls within the range given in the above table.
•
If the pressure is higher than 5 Bars (500 KPa) a pressure reducer must be installed.
•
If the average hardness of the water is higher than 10°FR, decalcified water must be used.
•
Each machine is supplied with rubber water supply hoses with 3/4"
•
Connect the pipe to the cold water supply
•
Do not shorten or damage the rubber pipes supplied with the machine.
•
Use the pipes supplied with the machine only.
Min/Max Table (for authorised and qualified persons only)
Pressure
................................................................................
Static press.
Dynamic press.
Hardness of supply water 0 °Fr – 10 °Fr
Temperature of supply water
Cold water
: 5 – 15 °C
2.3 Electrical connection (for the installer only)
Power supply cable: It is compulsory for the retailer - installer to adapt the insulation class of the power supply cable to suit the working
environment in compliance with Current Technical Regulations.
•
The electrical connection must be carried out in compliance with current technical regulations.
•
Make sure that the mains voltage reading corresponds to the voltage indicated on the machine plate.
•
An omnipolar magnetothermal switch sized to suit the absorption and with a contact opening of at least 3mm must be
installed.
•
Make sure that the electrical systems are efficiently earthed.
•
The terminal on the rear of the machine and identified by the relative symbol is for equipotential connections between
appliances (see rules for electrical plants).
FOR MACHINES WITH THREE-PHASE SUPPLY, FOLLOW THE INDICATIONS AND WIRING DIAGRAM ATTACHED TO THE
MACHINE ITSELF.
(for the installer only)
Min
KPascal(Bar)
250
(2,5)
200
(2,0)
23
Max
Kpascal(Bar)
500
(5,0)
400
(4,0)
DAQF028_rev0.10