INFORMATION SUR LA PLAQUE D'HOMOLOGATION
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION.
DIRECT VENT VENTED GAS FIREPLACE HEATER . APPROVED FOR BEDROOM, BATHROOM AND
BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF
INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES
GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE
MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE
SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND
COMMUNITIES, ANSI / NFPA 501A.
0-2000FT (0-610m)
22,000 BTU/h
16,000 BTU/h
15,400 BTU/h
EFFICACITE CONSTANTE: 70% VENTILATEUR ARRETE / 71% VENTILATEUR FONCTIONNE
NOT FOR USE WITH SOLID FUEL. FOR USE WITH
GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:
REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
FLOOR / PLANCHER
SIDES / COTES
BACK / ARRIERE
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE
INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR
DES EXTENSIONS PLUS GRANDES.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 12 INCHES AND 8 FEET RESPECTIVELY.
LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 12 POUCE ET 8 PIEDS
RESPECTIVEMENT.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
Pour l'emplacement de la plaque d'homologation, voir la section « VUE D'ENSEMBLE DE L'INSTALLATION ».
Cette illustration est à titre de référence seulement. Pour les renseignements exacts, consultez la plaque
d'homologation fi xée sur l'appareil.
W415-0662 / A / 05.24.11
GD33NR / CDV33NR
2000-4500FT(610-1370m)
20,000 BTU/h
16,000 BTU/h
15,400 BTU/h
* ALTITUDE DOWNRATING CONDITIONS APPLY TO CANADA ONLY / * LES CONDITIONS DE BAISSE D'EVALUATION SELON L'ALTITUDE S'APPLIQUENT AU CANADA SEULEMENT.
MANIFOLD PRESSURE: 3.5" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU
STEADY STATE EFFICIENCY: 70% FAN OFF / 71% FAN ON
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE.
ACTING THERMOCOU
CTING THERMOCO
D BY WOLF STEEL L
D BY WOLF STEEL L
COME IN CONTACT
ME IN CONTACT
URER WITH THE APP
URER WITH THE A
BUS
IBLES:
LES:
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
DEPTH
DEPTH
PROFONDEUR D
PROFONDEUR
0
VENT / EVENT
VENT
NT
0
MANTEL / MANTEAU
/ MANTEAU
ANTEAU
0
ON HORIZON
ON HORIZON
. REFER
. REFER
APPAREIL DE CHAUFFAGE AU GAZ VENTILÉ A L'EVACUATION DIRECTE. HOMOLOGUE POUR
INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO.
APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES
EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE
ET DE AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE
MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME
D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE
MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
9700539 (WSL)
4001657 (NGZ)
657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
001659 (WUSA)
01659 (WUSA)
MODEL
ALTITUDE / ELEVATION
ON
O
INPUT / ALIMENTATION
ATION
ATION
REDUCED INPUT / ALIMENTATION REDUITE
NTATION REDUITE
NTATION REDUITE
OUTPUT / RENDEMENT
ENDEMENT
NDEMENT
S DE BAISSE D'EVA
S DE BAISSE D'EVAL
N
N
MANIFOLD PRESSURE: 10" WATER COLUMN
MANIFOLD
MANIFOLD
EAU
EAU
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
PRESSIO
ESSIO
OLUMN
LUMN
MINIMU
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
NE D'EA
NE D'EAU
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
PRE
PR
ER COLUMN
COLUM
M
M
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
LONNE D'EAU
LONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
FF / 71% FAN ON
F / 71% FAN ON
STEADY STATE EFFICIENCY: 70% FAN OFF / 72% FAN ON
TEUR FONCTIONNE
FONCTIONNE
EFFICACITE CONSTANTE: 70% VENTILATEUR ARRETE / 72% VENTILATEUR FONCTIONNE
AFUE:
AFUE:
AFUE: 63%
63
6
AFUE: 63%
SE WITH
E WITH
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
UNIT ONLY.
UNIT ONLY.
AVEC CET APPAREIL. UTILISER AVEC LES PORTES
VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
RAPIDE. REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL
LTÉE. N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES
FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE
12"
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
1"
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
2" *
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A
NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION
PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE
LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-KT
SERIAL NUMBER/NO. DE SERIE:
S DE
DE
GUEUR AU
EUR AU
AUX ETATS-UN
AUX ETATS-UN
TUREES, TITRE 24 C
UREES, TITRE 24 C
PEUT ETRE APPLIQU
ETRE APPLIQU
ECURITE CONTRE
ECURITE CONTRE L'I
RES, LES SITES ET L
RES, LES SITES ET LE
(NGZ
GD33PR / CDV33PR
0-2000FT(0-610m)
2000-4500FT(610-1370m)
22,000 BTU/h
16,000 BTU/h
15,400 BTU/h
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION
GD/CDV33
20,000 BTU/h
16,000 BTU/h
15,400 BTU/h
W385-0244 / G