Télécharger Imprimer la page

Eureka MIGNON LIBRA Brew Manuel D'instructions page 28

Publicité

5.2.6
DOSE COUNTS
Upon powering on the machine, hold down the buttons (14)
a few seconds. The display shows the total grams dispensed in pairs of digits in
succession. For example, if the total number of grams dispensed in 163.4, the digits
00
00
16
34
appear on the display for two seconds. The top number indicates the
1
2
3
4
position of the pair of digits in the sequence.
5.2.7
DISPLAY CONTRAST ADJUSTMENT
Upon powering on the machine, keep the buttons (15)
to access the contrast adjustment. Buttons (14)
display to adjust the contrast from 1 to 10. To exit the adjustment, press one of the two
dose buttons.
5.3
GRINDING ADJUSTMENT
Turn the adjustment knob (3) clockwise to make the powder finer or anti-clockwise
to increase its coarseness. The adjustment must be made gradually, grinding a little
coffee every 2 notches at the most.
If the knob is turned by one full turn with the motor stopped, the machine may stop.
5.4
CUP FORK ADJUSTMENT
To adjust the cup bracket (6) loosen the cup bracket tightening screw (7) then raise or
lower the cup bracket (6) to adjust the height to the cup (10) (Fig. 6). Finally tighten the
cup bracket tightening screw (7).
The fork only fits the cup (10) supplied.
5.5
CUP FORK RECALIBRATION
Upon powering on the machine, hold down the buttons (15)
approximately 7 seconds to activate the calibration.
• Insert the cup (10) on the cup bracket (6). The sample weight will flash on the
display (default value 20gr). It is possible to modify the weight by acting on the keys
(14)
and (15)
• By pressing the key (17)
stop flashing.
• Insert the sample weight inside the cup.
• Press the keys (15)
calibration.
PLEASE NOTE: maintenance intervention only necessary in case of loss of calibration
precision
28
.
the system will acquire the tare value. The display will
and (16)
for a few seconds to complete the
and (16)
and (17)
and (15)
remain lit on the
and (16)
EN
for
pressed
for

Publicité