5.2.2
DOSE DISPENSING AND ADJUSTMENT
• After positioning the cup (10) on the cup bracket (6), choose the dose to be
dispensed by pressing the single dose (16)
(the selected button lights up).
• During dispensing, the display will show the value of the weight measured up to the
set value.
• During dispensing, the single (or double) dose button flashes.
ATTENTION
The selected dose key remains enabled for 15 seconds from positioning of the
cup. After 15 seconds, pressing the key, the grinding does not start and the
abbreviation "FH" appears on the display. To release the grinding, remove the
cup and reinsert it.
ATTENTION
If the cup is not inserted correctly, pressing the key grinding does not start and
the display shows the abbreviation "FH". To release the grinding, remove the
cup and reinsert it.
ATTENTION
The grinding must only start after inserting the cup or other container on the
filter holder fork.
• When dispensing is finished, the grinding grams of the dose return to the set value
and the counter is increased by the value of the ground grams.
• Press the buttons (14)
required for the selected dose (weight visible in grams on the display). The increase
or decrease in grams provided for the selected dose varies to a tenth of a gram.
• If the button (14)
weight of the selected dose is decreased or increased for the time of pressing.
To pause dispensing before the grinding time has elapsed, press one of
the two dose buttons again. The display shows the grams ground up to the
pause. To complete the dose it is necessary to press the dose button again.
26
and (15)
or (15)
, is held down for a few moments (long press), the
or double dose (17) button
to decrease or increase the coffee weight
EN