ELECTRICAL CONNECTIONS FOR PHOTO1 AND PHOTO2
SAFETY AND CONTROL DEVICE CONNECTORS
24 VAC
Accessory power supply 24VAC non-regulated 200mA MAX; not active during battery operation
24 VAC
COM
Common positive for FLASH - IND/ELEC - LED and accessories outputs
IND, gate open warning light output, 24VDC 5W MAX
IND/ELEC
ELEC, electric lock output 12VDC 15VA MAX
selectable with the
LED
Courtesy light output, 24VDC non-regulated 15W MAX also controllable via radio remote control
NEG
Negative power supply for accessories
Positive power supply for PH1 and PH2 photocells;
PH-POW
operating mode configurable with the
STOP/EDGE
8k2/NC safety edge contact input; operating mode configurable with the
STOP/EDGE
WARNING
PH2 opening photocell NC input; at any time during opening/closing, the intervention of the photocell (opening of the
contact) causes the movement to immediately stop. Closing the contact restores the opening operation. The operating
PH2
modes can be configured with the
WARNING
PH1 closing photocell NC input; at any time during closing, the intervention of the photocell (opening of the contact)
causes blocking and reversal of the direction of travel. While PH1 is active it is not possible to close the gate. The
PH1
operating modes can be configured with the
WARNING
OPEN
NO OPENING command input; MAN PRESENT function configurable with the
CLOSE
NO CLOSING command input; MAN PRESENT function configurable with the
NO PARTIAL OPENING command input;
PAR
MAN PRESENT function configurable with the
NO STEP-BY-STEP command input (SBS); upon each activation the commands AP (open) - ST (stop) - CH (close)
SBS
are executed in succession; the operating modes are configurable with the SBS SETUP parameter.
MAN PRESENT function configurable with the
COM
Common positive inputs PH2, PH1, OPEN, CLOSE, PAR, SBS
SHIELD
Antenna - shield
ANT
Antenna - signal
36
M2
PH2
PH2
TX
RX
2
1
parameter
with the
dip switch in the ON position the input is always disabled
with the PH2 dip switch in the ON position the input is always disabled
with the PH1 dip switch in the ON position the input is always disabled
PH1
PH1
TX
RX
2
1
parameter
parameter
parameter
parameter
parameter
parameter
parameter
parameter