4.7.1 - Error messages on the display
To cancel the error message on the display, after having eliminated the cause of the anomaly, perform a complete opening or closing
manoeuvre, i.e. until the relevant limit switch is reached. Alternatively, briefly press the MENU button (the automation does not perform
any movement).
MOTOR OVERLOAD
SAFETY EDGE
PHOTOCELL TEST
ENCODER
4.7.2 - Error messages on flashing light
The events reported in the following table are signalled by the flashing light and the KEY LED present in the control unit.
FLASHING INDICATION AND
LED KEY ON CONTROL UNIT
2 quick flashes + pause + 1 flash
4 quick flashes + pause, for three times
2 quick flashes + pause, for three times
5 quick flashes + pause, for three times
3 quick flashes + pause, for three times
6 quick flashes + pause, for three times
7 quick flashes + pause, for three times
4.7.3- Status messages on display
Repeatedly pressing the UP
status, press the
(MENU) button.
DISPLAY
,
I M1= 1200
I M2= 1200
CT20324 – FW 2.0 – SN 635A33F1
4.8 - Autolearning of the travel stroke
Upon the first start-up or in the event of a modification of the
equipment model, which involves restoring the factory values, the
message
learning procedure of the operating parameters must be performed
(width of the movement angle of the doors, slowdown points in
opening and closing, ...).
38
Obstacle detected
The photo test has failed
(UP) button displays additional information described in the following table. To return to the normal
,
,
, ecc.
appears on the display and the auto-
The current of a motor has increased very rapidly
1. The gate has struck an obstacle
2. Excessive friction in the movement of the leaf
The control unit has detected the activation of the safety edge
1. The safety edge is active
2. The safety edge is not properly connected
The photocell or safety edge test has failed
1. Check the correct functioning of the photocells
2. Check the photocell connections
The physical encoder does not respond
1. Check the correct operation of the encoder
2. Check the correct connection of the encoder
EVENT
DESCRIPTION
auto-learning
Auto-learning phase in progress
A leaf has struck an obstacle
Photo1 / Photo2
A photocell has been activated
Safety edge
The safety edge has been activated
The photocells or sensitive edge test has failed
Short circuit
Anomaly in one of the
overload
FLASH, ELS/SCA or LED outputs
Encoder Error
M1 or M2 motor encoder anomaly
MEANING
Automation status
Total number of complete opening + closing manoeuvres
Instantaneous current absorbed by motor M1, given in mA
Instantaneous current absorbed by motor M2, given in mA
Card type – firmware version – card serial number
WARNING
learning procedure (
parameters).
Select the correct motor before starting the auto-
paragraph 4.13 - Advanced