EN
10
11
230Vac
50/60Hz
1AT
2.5 - Model and technical data of the control unit
CODE
CE24BNC
• Electronic protection against short circuit and overload on the
FLASH, IND/ELEC and LED outputs
• Protection of 24VAC and PHPOW outputs via resettable fuses
• Automatic obstacle detection
TECHNICAL DATA
Power supply
Total maximum power of M1 and M2 motors
Maximum output current 24VAC
PHPOW maximum output current
Maximum FLASH output power
Maximum LED output power
Maximum power for the "IND/ELEC" output
Control unit fuse
Integrated radio receiver
Antenna
Number of saved transmitters
Can be used in saline, acidic or explosive
atmosphere environments
IP protection class
Overall dimensions
Weight
32
4
1
DESCRIPTION
Control unit for two 24 VDC gear motors for swing leaf gates
12
13
14
ON
9
3
2
6
5
• Auto-learning of travel length
• Disabling of unused safety inputs via dip switches: it is not
necessary to insert jumpers on the respective input terminals
(see paragraph 4.5)
CE24BNC
24 VAC (+10% -15%) 50/60 Hz
200 mA (24 VAC)
200 mA (24 VDC non-regulated)
15 W (24 VDC)
15 W (24 VDC)
5 W (24 VDC) / 15 VA (12 VDC)
1.6 AT (timed)
433.92 MHz OOK
RG58 wire or cable antenna
222 x 110 x 275 H mm
15
16
17
20
19
18
21
22
7
8
210 W
150
NO
IP54
340 g
ANT
SHIELD