2 - INTRODUCING THE PRODUCT
2.1 - Description of the product
RUN24 is a gear motor designed and built for use on swing leaf
gates. Paragraph 2.2 contains weight limits and maximum length
2.2 - Technical specifications
CODE
DESCRIPTION
RUN24
Gear motor for swing doors with a maximum length of 3m and up to 500kg in weight, 24VDC power supply
TECHNICAL DATA
MODEL
Torque
Cycles/Hour*
Opening time at 90°
Control board
Drive power supply
Motor power supply
Absorption
Engine power
Integrated lights
Degree of protection
Dimensions (L - D - H)
Weight
Operating temperature
Leaves maximum weight
Leaves maximum lenght
Sound emission level
* The cycles now indicated are intended with a non-paneled door at an ambient temperature of 20 °C.
2.3 - Description of the control unit
The CE24BNC control unit is the most modern and efficient control
device for two 24VDC Motorisation Plus gear motors for swing leaf
gates; any other use is to be considered improper and is therefore
prohibited. The CE24BNC control unit can also be configured to
operate with a single motor 24VDC.
2.4 - Control unit connectors description
1. Motor 1 (M1)
2. Motor 2 (M2)
3. Encoder input M1 and M2
4. 24VAC power supply for safety devices and accessories
5. 24VDC power supply (unregulated) for safety devices
(radio safety edge, photocells)
6. Connections for flashing light, electric lock/open gate indicator
light, courtesy light,
7. Inputs for safety devices (Safety edge/STOP, photocells)
8. OPEN, CLOSE, PAR, SBS control inputs
9. Status LED indicators: STOP/EDGE, PH2, PH1 safety devices
(red colour); OPEN, CLOSE, PAR, SBS controls (green colour)
10. Central power supply (secondary transformer 24VAC + PE)
of the leaf. Any other use is considered improper and is therefore
prohibited.
RUN24 MASTER
Nm
120
30
sec
14-20
CE24BNC
230 Vac, 50/60 Hz
Vdc
24
A
0,65
W
115
no
IP
44
mm
125 - 260 - 310
kg
10,5
°C
-20°+55°
kg
250
m
dB(A)
≤ 70
The 5-digit/14-segment display of the CE24BNC control unit
makes it easier to read the acronyms, facilitating programming
and monitoring of the automation; the menu structure allows easy
setting of work times and operating modes.
11. KBP/KBPN spare battery (optional)
12. SBK, fitting for connection to an energy
savings module
13. 1.6 AT fuse (timed)
14. EDGE/STOP, PH1, PH2 safety devices disabling
15. 5-digit/14-segment display
16. LED indicator (green colour) of radio functions or
error reporting
17. Antenna
18. Button
19. Button
20. Button
21. Button
22. Optional interfaces connector (Kube, PowerBus)
3
(UP)
(MENU)
(DOWN)
(SBS)
RUN24 SLAVE
120
30
14-20
-
-
24
2
50
no
44
125 - 260 - 310
10,5
-20°+55°
250
3
≤ 70
EN
31