1.4 Transportation
When taking your Aduro H1 home, please ensure that it travels in an upright position. Please use wood from
the packaging for the first use. The plastic packaging should be discarded.
You are welcome to install your Aduro H1 yourself – but we strongly recommend that you consult your
chimney sweep before you begin the installation. Your dealer can also provide you with installation advice. It
is important to ensure that all local rules and regulations, including ones relating to national and European
standards, are complied with when installing this device.
You may not begin to use the Aduro H1 until it has been inspected and
approved by your local chimney sweep.
2.1 Position of the hybrid stove/distance requirements
The new Aduro H1 must be installed in a suitable and physically possible position. You need to be sure that
the position complies with local regulations. Distance requirements will only apply if the Aduro H1 is to be
placed close to flammable materials. See below.
If the Aduro H1 is positioned against a brick wall or other non-flammable material, there is no minimum
distance requirement. To ensure cleaning, the optimal use of the convection air and access to inspection
openings and maintenance, there needs to be a distance of at least 10 cm to the wall behind and 60 cm to
the side. If you mount the stove closer to the wall than recommended above, you must be prepared to
dismount the flue pipe and turn the stove by the yearly inspection and by maintenance.
Distance to flammable material (see illustration)
Behind the stove
15 cm
2. Installation of the Aduro H1
To the sides of the stove
65 cm
To furniture
87,5 cm