Table 9. Protection Characteristics
UPS AC suppression joule
rating
UPS AC suppression
response time
Overload protection
Table 10. Battery Characteristics
Battery type
Battery voltage / AH
Battery charge current
Battery float voltage
Recharge time
Backup time
Low voltage shutdown
voltage
Min voltage for cold start
Hot-swappable battery
Table 11. Environment
Humidity
Storage temperature
Operating temperature
Operating elevation
Table 12. Weights and Dimensions
Net Weight, lb. (kg)
H x W x D, in. (cm)
Line Mode Overload Alert Condition - 110%±10%, goes to fault after 5 minutes; Overload Fault
Condition - 120%±10%, goes to fault immediately
Battery Mode Overload Alert Condition - 110%±10%, shuts down in 5 seconds; Battery Mode
Overload Fault Condition - 120%±10%, shuts down immediately
Sealed, maintenance-free, lead acid batteries.
8 hours From 10% to 90% capacity
0-90% RH @ 0-40 C (non-condensing)
4.0 × 7.4 × 12 (10.6 × 19.0 × 30.5)
Eaton Tripp Lite Series Cloud Connected UPS System User Guide 934927—Rev B
AVR750UNC (AG-0786)
316 (AC)
Instantaneous
AVR750UNC (AG-0786)
Qty (1) 12V / 9AH
1A (1.5A Max)
13.7 VDC
3 minutes at full load
11 minutes at half load
9.6V all load levels
10.6V
No
AVR750UNC (AG-0786)
-15 to +50 ℃
0 to +40 ℃
0-2000 meters
AVR750UNC (AG-0786)
17 lbs (7.3 kg)
Product Specifications