Turning the UPS On
3.
To detach the UPS from the wall, lightly push up on the bottom of the UPS to release it from the wall.
4.
Carefully lift the UPS off the wall.
2 2 . . 4 4
T T u u r r n n i i n n g g t t h h e e U U P P S S O O n n
For normal AC startup of the UPS, follow these steps:
1.
Connect the UPS AC power cord to a properly grounded NEMA 5–15R wall outlet.
NOTE
2.
Press the power button for half a second to turn on the UPS. The UPS will beep, and the green LED will
turn on and stay illuminated. The charger will engage as necessary, and the BATTERY BACKUP outlets will
begin passing line power.
3.
Plug your load equipment into the outlets on the UPS. There are two sets of outlets on your UPS. The
outlets marked SURGE ONLY do not provide battery backup power during power outages. Connect
everyday desktop items like printers, scanners, and other accessories not requiring battery support to
these outlets. The outlets marked BATTERY BACKUP offer UPS battery backup support during power
failures. The main outlet group, load one and two switched outlets, can be controlled via the Eaton Remote
Monitoring Application. Connect your vital computer equipment to these outlets.
NOTE
4.
Register your UPS at
2 2 . . 5 5
O O u u t t l l e e t t C C o o n n t t r r o o l l
The Eaton Tripp Lite Series AVR750UNC UPS System outlets can be switched on and off to control connected
equipment remotely. The outlet control is located in the Device Summary Screen of the Eaton Remote
Monitoring Application. (See
SURGE-ONLY protected outlets- do not provide battery backup power during power outages and are
powered directly from the input AC power source. There is no control of these outlets with the Remote
Monitoring Application.
Main battery protected outlets- controlled by the Device control option in the Remote Monitoring
Application or by pressing the UPS ON/Off button.
Switched battery protected outlet Load one / Load two– controlled by the UPS output control button
in the Remote Monitoring Application or by pressing the UPS ON/Off button.
2 2 . . 6 6
T T u u r r n n i i n n g g t t h h e e U U P P S S O O f f f f
To turn off the UPS, hold the power button on the front panel for half a second; the UPS will beep, indicating it
is in Standby Mode. Unplug the UPS from the power source.
NOTE
6
Eaton Tripp Lite Series Cloud Connected UPS System User Guide 934927—Rev B
Once the UPS is plugged into a wall outlet, the battery charger will engage as
necessary, and the SURGE ONLY outlets will begin passing power.
The Tripp Lite Series AVR750UNC UPS system is designed to support electronic
equipment only. You will overload the UPS if the total volt-amp (VA) ratings for all the
equipment connected to the outlets exceeds the UPS output capacity. To find your
equipment's VA ratings, look at its nameplate. If the equipment is listed in amps (A),
multiply the number of amps by 120 to determine VA. For example 1A × 120 = 120VA. If
you suspect you have overloaded the outlets, remove some equipment.
tripplite.eaton.com
.
Figure
38).
If the UPS is not unplugged from the wall receptacle, it remains in Standby Mode, and
the SURGE ONLY outlets will still pass line power.