Hook up the handset of apartment station C1 (or press the audio button again). It will beep to indicate
exit from programming mode.
§
The other functions will not be lost if the buttons are programmed for this function because the
intercom call is made with the handset off-hook.
1b) With handset on-hook.
–
Hold the • button pressed for longer than 5 seconds. The yellow LED will blink slowly to confi rm that
programming mode is selected. In all cases, the device will quit programming mode and save any
changes after 10 minutes.
–
Press the button to be programmed for at least 3 seconds, until the confi rmation tone sounds.
–
Go to the apartment station that the button will call (apartment station C2) and press the door opener
button. The apartment stations C1 and C2 will be beep to indicate that they have been programmed.
–
Hold the • button pressed for longer than 5 seconds to quit programming mode.
–
Check the programmed function: release the handset C1 and press the programmed button.
Check that the apartment station C2 rings and check audio.
–
You will need to program apartment station C2 to call C1 to make the opposite call possible.
§
Refer to the booklets provided with the apartment stations for how to change the calling tones.
PROGRAMMING DATA DELETION
Deleting door unit data:
1. Access advanced programming.
2. Hold any calling button pressed for at least 5 seconds (after the second emitted beep), then release it.
3. Return the switches to the working position.
In this manner, the button-user association setting, the special function button association setting and
the number of surveillance cameras are deleted.
Deleting apartment station data:
Refer to the booklets provided with the apartment stations for deleting door phone and video door phone
settings (intercom calling codes). .
DOOR UNIT ERROR INDICATIONS
The following indication may appear on apartment stations when existing advanced confi guration mode:
•
Several door units with the same ID: buzzer error tone: repetitive beeps.
42
All manuals and user guides at all-guides.com
C2
DS1083-029E