Télécharger Imprimer la page

Urmet 1083 Notice page 10

Publicité

station when an audio conversation has been established or when after having received a call or auto-
on function either a video connection has been established or during the call pick-up time.
"Free": the electric lock may be activated by pressing the door opening button on the call station if this
is confi gured as main or if this confi gured as secondary and the user belongs to the same column as
the calling station. This function is typically used for secondary stations.
When a door open command is received from the switchboard.
Name tags, if powered by the ILL terminal of the apartment station will go out while the electric lock is
actuated.
GARAGE DOOR LOCK MANAGEMENT
The calling station have two terminals connected to the contacts of a normally open relay which can be
used to control a gate opening control unit (1). The relay is operated for 1 second after receiving the garage
door opening command according to the operating mode ("free" or "privacy") as the door lock.
(1) The relay is not suitable to control direct power loads and can only be used as control relay. Refer to the
calling station manual for electrical features.
VIDEO SURVEILLANCE AND ACCESS CONTROL FUNCTIONS
SURVEILLANCE CAMERA AUTO-ON FUNCTION (for calling stations with correct setup only)
Users can switch the video door unit on by pressing the button dedicated for this function on the apartment
station (typically the
(terminals V3, V5). Up to 5 cameras connected to the calling station may be used with a video switching
device 1038/69 or 1083/69. The user can press the button to cyclically view the images of the surveillance
cameras on the main calling station with ID equal to 0, then in sequence the images of other main calling
stations, fi nally the cameras of the secondary stations of the column to which it belongs.
DOOR SENSOR MANAGEMENT FOR OPEN DOOR FUNCTION
The door units have two terminals for managing an NC open door sensor (SP, CT). The apartment units
provided with indicator LED may use the red LED to indicate the state of the door of the last calling station
and opened by pressing the door opening button. The LED will light up if the door of the main calling station
is open and will blink if the secondary calling station door is open.
DOOR OPENER CODES
4-digit door opening codes (without time restraints) for each user and general codes (with time restraints) can
be programmed on calling modules. Refer to the calling module instruction manual for more information.
APARTMENT STATION PERFORMANCE
§
For specifi c features of each door unit, see its instruction manual.
RECEIVING A CALL
The user's apartment station will ring with one of the fi ve possible ring tones when a call is received for the
following times:
Source of the call
Call from main station
Call from secondary station
Call from switchboard
Intercom call
The fl oor call is the same as a main station call in terms of duration but a different tone is used:
Floor call
10
All manuals and user guides at all-guides.com
button). Up to two surveillance cameras can be connected to the calling stations
Time
3 s ON
0.4 s ON 0.2 s OFF repeated fi ve times
0.1 s ON 0.05 s OFF repeated three times
pause 0.2 s repeated fi ve times
0.5 s ON 0.5 s OFF repeated three times
3 s ON
Total duration of the tone
3 s
2,8 s
2,8 s
2,5 s
3 s
DS1083-029E

Publicité

loading