Exit from the advanced confi guration, by setting again the switches in the positions used to program the
door lock release time and the guaranteed conversation time: the yellow led turns off.
Example:
The secondary call module "A" only calls users form 0 to 10 and the "B" only users from 11 to 18.
On the call module "B" access to advanced confi guration;
Set the ID dip-switch to 11;
Move the AUX dip-switch no. 5;
Set again all the dip-switches in their previous position;
Exit from the advanced confi guration.
2Voice
power supply
6 BASIC FUNCTIONAL TEST
The functional system test may be started after having checked that all power supplies are correct and
that all the line terminations are correctly inserted. The test consists in calling all users from the door units,
checking that all apartment stations of the called user ring, checking for presence of picture for video calls,
checking audio and checking operation of the electric lock of the door and garage.
1. Press a calling button on a main calling station.
The door unit will output a tone to indicate that the call has been forwarded.
2. Check the following when a call is received.
The user's extension 0 will ring and the caller's picture will appear on the display. The user has 60
seconds to reply by picking up the handset or pressing the audio button (for hands-free apartments
stations).
No picture will appear on extensions 1, 2 and 3 if there are several apartment stations in parallel. Press
the auto-on button (button ) to switch on another video door phone ("video switching" function). This
operation can be repeated on all called user's monitors until the 60 second call timeout or until one
of the handsets defi nitively picks the picture up.
A conversation which can last for up to 10 minutes will be established after picking up.
The electric lock of the door and of the garage can be operated by pressing the specifi c buttons from
the time of the call to the end of the conversation.
3. End the conversation by hanging up the handset or pressing the audio button again (on hands-free
apartment stations). The system will return to standby mode.
4. Repeat these operations for all users in the system.
5. Repeat the operations from step 1 on all stations if there are other calling stations in the system.
Remember that the monitors will not be operated if the door unit is not a video unit.
7 OPTIONAL PROGRAMMING FOR ADDITIONAL FUNCTIONS
The following programming operations are needed after testing the basic operation of the system only if the
following functions are required:
1. Surveillance camera auto-on function: program this function in the presence of surveillance cameras
connected to one or more calling stations.
2. Door unit button association for special function.
38
All manuals and user guides at all-guides.com
column
interface
ID = n
"B"
Secondary call module with 8 buttons
ID = n
AUX dip 2 = 1
offset = 11
Called users: from 11 to 18
Secondary call module with 11 buttons
ID = n
AUX dip 2 = 0
offset = 0
Called users: from 0 to 10