ELECTRICAL CONNECTION
3. Make the AC electrical connections inside the electrical enclosure as per wiring diagram.
WARNING: Products must be wired to a Class A 20 Amp GFCI (Ground Fault Circuit Interrupter) protected circuit when used in
bathrooms and all other locations required by the National Electric Code.
3
4. Make the DC electrical connections inside the electrical enclosure using the supplied DC Cable [219-1803] as per wiring diagram.
4
NOTE: If a remote installation of the electrical enclosure is required, reference the Remote Power Supply Instructions by following the
QR code below. A 15' remote DC cable [RPS-EXTEND15] is available (not included) and required for a remote installation.
© 2024 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
CIRCUIT BREAKER
BLACK
120VAC
20A GFI
WHITE
GROUND
INSTINCT MIRROR
[209-1470]
Remote Power
Supply Instructions
FIELD CONNECTION
FIELD CONNECTION
[RPS-EXTEND15]
15' Remote DC Cable
8
ELECTRICAL ENCLOSURE
BLACK
LINE/BLACK
WHITE
NEUTRAL/WHITE
GROUND
ELECTRICAL ENCLOSURE
-
BLACK
24v DC
RED
24v DC +
Part no. 209-1471 09/16/2024