PIXEL UP: 40414.S
2.
Installation
The RJ45 network interface is to be connected exclusively to a SELV (Safety Extra-Low Voltage) network. The Power-over-Ethernet
(PSE) power supply unit must provide electrical insulation between any accessible conductor including the earth wire, if there is one,
and all the contacts of the network ports, including those not used by the PSE or by the device to be installed.
1. Install the flush mounting or external surface mounting box at a height of approx. 1.65 m or 1.20 m for accessibility for the disa-
bled, from the upper edge of the box to the floor.
2. Connect the power supply (PSE) Power over Ethernet (PoE switch or injector) to the RJ45 network interface using the Ethernet
cable.
3. Close the panel, fixing the front cover plate to the box using the screws.
4. Complete the configurations using the Web configuration interface.
For installation see also the figures given below, in the last pages of this manual (pag. 51, 52, 53).
Rear view
IP units
audio/video
41007UP
Display
41018UP
Alphanumeric
keyboard
41019UP
Terminal block for connection tot he audio/video unit
Terminal functions
Programmable input (in NO or NC mode)
CA+
via Web configuration interface (functions:
command for lock opening or OUT1/OUT2
actuation). Connect to a SELV-type insulated
CA-
dry contact.
S+
Electric lock output
S-
RJ45 interface for connection cable to the
system network
Terminal block for connection to display
Terminal functions
Programmable input (in NO or NC mode)
CA-
via Web configuration interface (functions:
command for lock opening or OUT1/OUT2
actuation). Connect to a SELV-type insulated
CA+
dry contact.
Terminal block for connection to keyboard
Terminal functions
NO
Relay output with NO and NC contacts cho-
sen by the installer.
The contact can control resistive loads exter-
C
OUT1
nally powered with maximum current 1 A and
maximum voltage 48 Vdc (maximum voltage
NC
permitted by EN 62368-1 for the ES1/SELV).
Relay output with NO and NC contacts cho-
NO
sen by the installer.
The contact can control resistive loads exter-
OUT2
C
nally powered with maximum current 1 A and
maximum voltage 48 Vdc (maximum voltage
NC
permitted by EN 62368-1 for the ES1/SELV).
EN
11