7. TROUBLESHOOTING:_________________________________________________________
Any action required to solve possible problems in the equipment should always be performed with
the equipment disconnected from the mains. Any problem not indicated in the following list should
be solved by a qualified technician.
PROBLEM
Production indicator always indicates "0" at all
production levels
It is not possible to turn on the power supply.
Free chlorine levels in the water are very low.
SOLUTION
Check the electrodes.
Verify connections between power supply and
the electrolysis cell.
Check salt concentration.
Check that the system is properly connected to
230 V/50-60 Hz in the control box of the pump.
Check the estate of the fuse located at the
bottom of the power supply.
Check that the system produces chlorine in
pool jets.
Verify that the water Chemicals parameters
(pH, combined chlorine, isocyanuric acid, etc.)
are correct.
Increase filtering time.
Add chlorine stabilizer (cyanuric acid) until a
concentration of 25 – 30 g/m
41
is achieved.