EN
1.- Filter
2.- Switchbox
3.- Other equipment (heating system, UV, etc.).
4. INSTALLATION:______________________________________________________________
4.1. Installation of the power supply
Always install the POWER SUPPLY of the salt electrolysis system VERTICALLY on a solid and rigid
surface (wall) as shown in the recommended installation diagram (Fig. 1). In order to guarantee
a good state of conservation, the POWER SUPPLY should be installed in a well-ventilated dry
place. Due to IP degree of the POWER SUPPLY the salt electrolysis system should not be installed
outdoors. The POWER SUPPLY should be installed a bit distant from the electrolysis cell so that it
cannot accidentally suffer water splashes.
Fig.1 Recommended installation diagram.
Warning
Beware of corrosive atmosphere formation due to pH minus solutions
(especially, those ones based on hydrochloric acid "HCl"). Do not install
the salt electrolysis system near to any stores of these chemicals.
We strongly recommend the use of chemicals based on diluted sulphuric
acid. Power supply must be connected to the electrical control box of the
pool, so that the pump and the salt electrolysis system are turned on
(and off) simultaneously.
4.- Pump.
5.- Electrolysis cell
6.- Power supply
28