Télécharger Imprimer la page

Zodiac EiSalt Serie Notice D'installation Et D'utilisation page 37

Publicité

WINTER Mode: during periods of low water temperature, where the chlorine demand will
be low, select a production level of 50%, because in this way power consumption and
lifetime of the package of electrodes are optimized.
5.3. TEST Mode Polarity Reversal
To enter in TEST mode, lower the production level to "0%" successively pressing the "POWER
SELECTOR" [2] key (Fig. 15).
Once the system has stopped, hold down this key for 10 seconds. The system will indicate that it
has entered TEST MODE and all the leds will light up for one second.
Next select the desired production level through the "POWER SELECTOR" [2] key.
When the system is in TEST mode, the "0%" light will sequentially vary its intensity.
In TEST MODE, the system resets the polarity reversal and the chloration level selected. In this
mode the system is fully operational, making polarity reversal of the electrodes every 2 minutes.
To quit TEST MODE, the system must be switched off from the mains for a few seconds.
Switching on the system again, it automatically returns to the previous self-cleaning program.
Fig. 14
Fig. 15
37
EN

Publicité

loading

Ce manuel est également adapté pour:

Eisalt 12Eisalt 21Eisalt 30