Mounting the mains rectifier
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
 Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
 The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be pre-
sent for installations in closed housings.
 The air intake on the underside or the air outlet on the back of the device
must remain clear.
 The installation surface must be level and sufficiently sturdy.
➤ Secure the mains rectifier with the fastening bracket (fig. 2, page 3).
7
Using the mains rectifier
NOTICE!
A
 Do not reverse the polarity. If the poles are reversed device may
overheat and be damaged.
 Replace defective fuses with new ones of the same rating (4 A
slow-blow).
➤ Fit wire sleeves to the ends of wires which you wish to connect to the
mains rectifier.
NOTE
I
To avoid drops in voltage and therefore performance, keep the ca-
ble route as short as possible and only disconnect it when neces-
sary.