6.1
Guard function
Check guard for proper closing before each use. Do not operate the saw if guard does not
move freely and enclose the blade instantly. Never clamp or tie the guard so that the blade
is exposed. If saw is accidentally dropped, guard may be bent. Check to make sure that
guard moves freely and does not touch the blade or any other part, in all angles and
depths of cut.
Check the operation and condition of the guard return spring. If the guard and the spring
are not operating properly, they must be serviced before use. Guard may operate
sluggishly due to damaged parts, gummy deposits, or a build-up of debris.
Assure that the base plate of the saw will not shift while performing the "plunge cut" when
the blade bevel setting is not at 90°. Blade shifting sideways will cause binding and likely
kick back.
Always observe that the guard is covering the blade before placing saw down on bench or
floor. An unprotected, coasting blade will cause the saw to walk backwards, cutting
whatever is in its path. Be aware of the time it takes for the blade to stop after the switch is
released.
7 ADDITIONAL SAFETY INSTRUCTIONS FOR LASERS
Warning! The laser beam potentially causes severe eye damage. Never look or stare
directly into the leaser beam.
During use, do not point the laser beam at people, directly or indirectly through reflecting
surfaces.
This laser complies with class 2 according to EN 60825-1:2007. The unit includes no
servicing components. Do not open the housing for any reason. If the unit is damaged,
have the damage repaired by an authorized repair agent.
8 ADJUSTMENTS
8.1
Replacing the saw blade (Fig. 1)
Only use sharp and undamaged saw blades. Cracked or bent saw blades must be replaced
immediately.
Place this circular saw on its side on a flat surface. Advice you bring the base plate (10)
down as if a minimum depth cut which is ease to operate.
Push the spindle lock button toward motor housing as the arrow shows in Fig. 1 and firmly
hold it.
Turn the blade clamp bolt anti-clockwise by using the hex key that supplied with the tool.
Remove the blade clamp bolt and outer flange.
Raise the lower guard (16) by using the lever for lower guard (17), and then remove the
saw blade.
Clean the saw blade flanges, then mount the new saw blade onto the output spindle and
against the inner flange.