Télécharger Imprimer la page
Masquer les pouces Voir aussi pour piCOMPACT 23 SMART:

Publicité

Liens rapides

Installation manual
piCOMPACT
23 SMART
®
IO-Link, 3-4 channels

Publicité

loading

Sommaire des Matières pour piab piCOMPACT 23 SMART

  • Page 1 Installation manual piCOMPACT 23 SMART ® IO-Link, 3-4 channels...
  • Page 2 This manual is available in the following languages at piab.com Chinese English French German Italian Japanese Korean Polish Portuguese Russian Spanish Swedish Page 2/28 Page 2/28 piCOMPACT 23 SMART IO-Link 3-4 channel Manual ®...
  • Page 3 Contents 1. Introduction to the manual ..4 About the manual ....4 1.2 Safety signs used in the manual ..4 1.3 Target group .
  • Page 4 SMART, please visit www.piab.com. This manual is SMART, please visit www.piab.com. This manual is also available to download at www.piab.com in the 12 also available to download at www.piab.com in the 12 languages shown on page 2. The original instructions languages shown on page 2.
  • Page 5 Introduction to the manual 1.4 Compliance 1.4.1 Compliance for NC and NO 1.4.2 Compliance for bi-stable European Directives, CE European Directives, CE Directive Standard detail and/or Directive Standard detail and/or measurement reference measurement reference Electromagnetic EN/(IEC) 61000-6-2:2005 Electromagnetic EN/(IEC) 61000-6-2:2019 Compatibility EMC) EN/(IEC) 61000-6-4:2007+A1 Compatibility EMC)
  • Page 6 Safety instructions 2. Safety instructions port due to the risk of ejected objects, and piCOMPACT 23 SMART is intended to be damage of the product. ® incorporated into machinery or to be assembled with • Do not restrict or block the exhaust, to avoid other machinery to constitute machinery covered by product damage and application failure.
  • Page 7 Safety instructions Utilisation inadaptée Avertissement ! Vacuum force Ne pas utiliser l’appareil s’il est endommagé. Ne L’utilisation irresponsable d’air Débit d’aspiration pas utiliser l’appareil pour créer du vide ou comprimé peut causer des blessures. souffler de l’air à d’autres fins que celles qui sont Vakuumkraft L’air comprimé...
  • Page 8 Safety instructions Die Wartung muss gemäß den Anweisungen in internationale Hebenormen zu erfüllen. Verwenden capelli e occhi lontani da connessioni di diesem Handbuch durchgeführt werden. Sie das Produkt nicht zum Absaugen von aspirazione e scarico. • Unterbrechen Sie vor Wartungsarbeiten die Flüssigkeiten.
  • Page 9 Safety instructions • Gdy jednostka wytwarza podciśnienie, mantenimiento del producto deben ser realizados port próżniowy i wylotowy nie mogą zostać únicamente por personal con experiencia y Produkt piCOMPACT®23 SMART przeznaczony zablokowane. Ma to zapobiec wyrzucaniu especialmente formados. jest do integracji z maszyną lub montażu z innym przedmiotów, uszkodzeniu produktu oraz urządzeniem w celu stworzenia nowej instalacji, Antes de montar y desmontar los componentes,...
  • Page 10 Safety instructions de problemas se realizará de acuerdo con las instrucciones del manual. VARNING! Uso incorrecto No utilice el producto si está dañado. El producto • no se utilizará para crear vacío ni soplar con otras Installera eller använd inte din piSAFE® som finalidades ajenas a las previstas.
  • Page 11 SE-18212 DANDERYD SWEDEN 3.1.1 Identification label Each unit is identified by a label with identification information. For any communication with Piab AB or service centers always refer to the label information. 3.2 Product overview Overview, IO-Link 3-4 channels Figure 1 Overview, IO-Link 3-4 channels Pos.
  • Page 12 Installation 4. Installation 4.1 Connections Connections, 3-4 channels Figure 2 Connections, 3-4 channels. Pos. Description Size Compressed air (common feed) Push-in: Ø6 / Ø1/4’’ / Ø8 (Ø5/16’’) / Ø10 / Ø3/8” Vacuum port (1-3 ports) Push-in: Ø10 / Ø3/8’’ / Ø12 / Ø1/2’’ Barb: Ø12 /Ø1/2’’ Vacuum port (1-3 ports) Push-in: Ø10 / Ø3/8’’...
  • Page 13 Installation 4.2 Pneumatic diagrams Note! Filter and vacuum sensor are optional 4.2.1 NC and NO Vacuum NC Vacuum NO • • Without non-return valve • • • • With non-return valve • • Figure 3 Compressed air, 2. Vacuum, 3. Exhaust. Manual piCOMPACT 23 SMART IO-Link 3-4 channel...
  • Page 14 Installation 4.2.2 Amplified blow-off (ABO) Vacuum NC Vacuum NO & Blow-off NC & Blow-off NC • • • • Without non-return valve • • • • • • • • • • • • With non-return valve • • • •...
  • Page 15 Installation 4.2.3 Vacuum hovering (PVH) and amplified blow-off (ABO) Vacuum NC Vacuum NO • • Without • • non-return valve • • • • • • • • • • • • With • • non-return valve • • • •...
  • Page 16 Installation 4.2.4 Pneumatic diagram, bi-stable Vacuum bi-stable Vacuum bi-stable & Blow-off NC & Blow-off NC + ABO Without non-return valve With non-return valve Figure 6 Compressed air, 2. Vacuum, 3. Exhaust. Page 16/28 piCOMPACT 23 SMART IO-Link 3-4 channel Manual ®...
  • Page 17 Installation 4.2.5 Pin configuration with IO-Link For detailed information about IODD, see IODD manual, item number 0207381 on www.piab.com. See the manual for your configuration on www.piab. com for more information M12 5p Class A Figure 7 Pin configuration with IO-link.
  • Page 18 Installation 4.2.6 Pin configuration with separate power domains M12 5p Class B Figure 8 Pin configuration with separate power domains. Pin No. Name Description Note V+sys Supply voltage, 24 VDC (V+) Not connected Common, 0 VDC (V-) IO-Link Not connected Page 18/28 piCOMPACT 23 SMART IO-Link 3-4 channel...
  • Page 19 Lights only when activated from IO. Indicator LED - Green, Blow-Off valve Lights only when activated from IO. *Override function for Automatic Condition Monitoring (ACM). See the manual for your configuration on www.piab.com for more information. Manual piCOMPACT 23 SMART IO-Link 3-4 channel Page 19/28...
  • Page 20 Installation 4.3 Mounting 4.3.1 3-4 channels 29.3 2.953" 1.154 " Figure 10 3-4 channels. Page 20/28 piCOMPACT 23 SMART IO-Link 3-4 channel Manual ®...
  • Page 21 Installation 4.3.2 Split, manifold mount 2.953" Figure 11 Split, manifold mount. Unit 3 ch 4 ch mm [in] 89 [3.50’’] 112 [4,4’’ Manual piCOMPACT 23 SMART IO-Link 3-4 channel Page 21/28 ®...
  • Page 22 Technical data 5. Technical data Pneumatic technical information Description Unit Value COAX ® SX12 COAX ® SX42 Feed pressure, pump at opt. MPa [psi] 0.50 [72.52] 0.52 [75.42] 0.47 [68.17] 0.57 [82.67] Feed pressure, nozzle at opt. MPa [psi] 0.5 [72.5] 0.43 [62.4] Max vacuum at opt.
  • Page 23 Warranty 6. Warranty The Seller gives its Customers a one-year warranty It is at the Seller’s discretion whether a faulty from the receipt of the Products, accessories, Product should be returned to the Seller for control devices end Kenos products included. replacement or if it should be repaired by the Seller ®...
  • Page 24 Environmental aspects are considered in the development process of Piab’s products to make sure that a minimal environmental footprint is used. Piab is certified against with ISO-14001, and also complies with REACH (EC 1907/2006). The ways of handling recycling and disposals vary...
  • Page 28 Brazil China Lagny sur Marne Danderyd (HQ) Sao Paulo Shanghai +33 (0)16-430 82 67 +46 (0)8-630 25 00 +55 (0)11-449 290 50 +86 21 5237 6545 info-france@piab.com info-sweden@piab.com info-brasil@piab.com info-china@piab.com Mölndal Germany Canada India Ergonomic Handling +46 (0)31-67 01 00...