D3
L20
L23
T5
Figure 9 - Generator control panel
•
When the wire feeding unit is connected, the
displays D3 and D4 show the welding para-
meters during working. The T5 key and the
E3 knob are disabled, L17, L18, L19 LEDs
are active and replicate the functions of L4,
L5, L6 LEDs.
•
When the wire feeding unit is disconnected,
MMA, TIG and MIG CV functions are ena-
bled on the generator.
L17 Powered generator green LED
When ON, the generator is properly powered and
ready for use. When blinking, it means that the
generator is temporarily unusable due to an alarm
or a change in the welding process.
L18 Thermal alarm LED
lights up if the generator overheats.
Note: do not power off the generator and let it cool
down.
L19 Inverter ON LED
generator on welding
L20 MMA or TIG Lift process LED
L21 Regulation LED of Hot-Start in MMA
L22 Regulation LED of Arc-Force in MMA
or of the Inductance in MIG CV
L23 MIG CV process LED
T5
Navigation key
E3
Regulation knob
D3-D4
Parameters display
L17
L18
L19
T6
T7
Figure 10 - Gas Test / wire feeding buttons
Inside the separated wire feeding unit or inside the
spool compartment in the compact generators there
are two buttons with the following fucntions.
T6
Gas test button
T7
Wire feed / wire fast loading button
EN-11
D4
L21
E3
L22