L5
Thermal alarm LED
lights up if the generator overheats.
Note: do not power off the generator and let it cool
down.
L6
Inverter ON LED
generator on welding
L7
Voltage LED [V]
lights up when the parameter of the welding voltage
is displayed on D2, this is expressed in [V].
Note: by welding, L7 is always ON and D2 displays
the instantaneous arc voltage.
L8
Balance LED
lights up when the value of the voltage compensation
applied to the synergic curve is displayed on D2. This
LED only works in Synergic Mig.
L9
Parameter LED
lights up when any other parameter not indicated by
the previous LEDs is displayed on D1.
L10 MIG process LED
Continuous wire welding
L11 MMA process LED
Manual Metal Arc or coated electrode
L12 TIG process LED
TIG Lift by contact arc strike
L13-L14 MIG 2T and 4T welding mode LED
ON= confirmed parameter
Fast blinking= parameter being changed
Slow blinking= Plus 2T or Plus 4T mode enabling
L15 Electronic inductance LED
ON= confirmed parameter
Fast blinking= parameter being changed
L16 RAPID SETUP MENU LED
Accessible only by pressing and holding the key T3
(see section BASIC SETUP)
E1-E2 Regulation knob
D1-D2 Display
Parameter visualization
T1
Selection key
Short press: selection of the parameters to be
displayed (only by Synergic MIG)
Long press: JOB LIST
T2
MODE key
Selezione del processo di saldatura
Conferma variazione parametro
T3
SETUP key
Short press: welding functions access (2T-4T/Inductance/
Spot)
Long press: RAPID SETUP MENU access
T4
Save & Recall key
Parameters saving and recalling
EN-10