Télécharger Imprimer la page

Castolin Eutectic DERBY 426 Manuel D'instructions page 27

Publicité

TROLLEY MOUNTING AND INSTALLATION
Follow the mounting instructions supplied with
the trolley to install the welding unit, compact
or with separate wire feeder and the cooling
unit.
WATER COOLER CONNECTION
Important: read also the Operating instruc-
tions supplied with the water cooler before
connecting it to the welding unit.
Remove the metal plate on the back side of
the generator to enter the compartment -
for the water cooler connection.
Figure 1 - Connector for water cooler on the generator
Refer to the Assembly Paragraph for the unit's
installation, for the connection of the hose-
pack and of the water cooler (if present).
Load the wire, connect the gas cylinder and
replace the wire liner if necessary, as descri-
bed in this paragraph.
Check line voltage and connect power cable.
For generators with water cooling unit:
Check the level of coolant in the cooling unit
and turn it on.
Power ON the welding unit. The display shows
the screen of the last welding process perfor-
med by the unit.
Check for the water cooling unit enabling on
the Basic Setup Menu before proceeding.
ASSEMBLY
O
PREPARATION FOR WELDING
Make the connection of the power cable and
of the pressostat through the rapid connec-
tors and close the compartment with the new
metal plate.
Important: The water cooler is activated
from the menu "Basic Setup". Refer to "Ba-
sic Setup" section.
HOSEPACK CONNECTION
Connect the plugs of the interconnecting ho-
sepack to the Positive Sockets -
power generator and -
-
Connect the military connectors of the inter-
connecting hosepack to the Sockets -
the wire feeder and on the power generator.
For generators with water cooling unit:
Connect the blue water feed hose of the in-
terconnecting hosepack to the connections
marked in blue -
feeder and water cooler.
Connect the red water feed hose of the in-
terconnecting hosepack to the connections
marked in red -
feeder and back side of the water cooler.
EARTH CABLE AND TORCH CABLE
CONNECTION
Ensure unit is powered off and unpluged
from the mains.
Connect the earth cable to the negative cur-
rent socket – C – of the power source.
Plug the torch hose into the socket – A –
on the front of the welder having care to not
damage the contacts and secure by hand
screwing in the threaded connection.
EN-5
- on the
B
- on the wire feeder.
L
- on the back side of wire
K
- on the front side of wire
K
- on
J

Publicité