During storage
Sampling
Breath volume
Breath flow
Breath duration
Measurement accuracy
Standard deviation of repeatability with ethanol standard
Up to 0.50 mg/L
≥0.50 mg/L
Up to 1.00 ‰
≥1.00 ‰
Sensitivity drift
Typically 0.4 % of the measured value per month
Wait time for measurement readiness following a previ-
ous measurement of:
0.00 mg/L: 2 s
0.25 mg/L: 20 s
0.50 mg/L: 40 s
1.00 mg/L: 80 s
>1.50 mg/L: 120 s
Adjustment
Recommendation: every 6 months (local deviations possi-
ble)
Dimensions
50/60 mm × 141 mm × 31 mm (W × H × D)
Weight:
approx. 150 g
Power supply
1 × 3 V CR123A
The battery is designed for up to 1500 measurements
(depending on use and ambient conditions)
Protection class
IP 54
Interface
Micro-USB, 2.0 fullspeed; for service personnel only
CE marking
Electromagnetic compatibility
Configuration possible, see nameplate
Instructions for use
|
Dräger Alcotest 6000
-20 °C to +60 °C
(-4 °F to +140 °F)
15 to 75 % RH (10 to 100 % RH
<48 h)
>1.2 L (default setting)
>10 L/min (default setting)
>1.6 s (default setting)
0.008 mg/L or
1.7 % of the measured value
0.017 ‰ or
1.7 % of the measured value
depending on which value is
higher
0.00 ‰: 2 s
0.50 ‰: 20 s
1.00 ‰: 40 s
2.00 ‰: 80 s
>3.00 ‰: 120 s
|