15.5
Electrical connection
Dangerous electrical voltage!
The machine may only be connected to the power supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
•
Check, whether the neutral connection (if existing) and the protective grounding function
properly.
•
Check, whether the supply voltage and the frequency correspond to the specifications of
the machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
Use a supply cable that fulfils the electrical requirements (e.g. H07RN, H05RN) and take the
•
required cross-section of the supply cable from a current carrying capacity table. Pay
attention to the measures for protection against mechanical damage.
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
• Remove the limit screw (1)
• Slide the bracket planer fence (2) bracket onto the
guadience planer fence (4)
• Position the planer fence (3)
• Fix the planer fence in desired position with the
clamping lever (5) and clamping screw (6)
• Fix the limit screw(1) again
NOTE:
Parallelism can be adjusted with adjusting nuts (7):
• Slightly loosen the assembly nuts
• Adjust parallelism
• Tighten the assembly nuts again
• Insert the 2 groove stones of the planing shaft cover (8)
into the lower groove of the planer and fix it with 2
screws (9)
2. Assembly arm planer knife cover
• Push the arm planer knife cover (1) onto the holder (2)
at the exit planer table (3) and fix it with the screws
• Fix it with clamping lever (4) in desired position
3. Assembly planer knife cover
• Insert planer knife cover (1) into the holder (2) and fix it
in desired position with the fixing knop (3)
WARNING
N O T E
HOB410PRO_400V | HOB410PROSMW4_400V
ASSEMBLY
37