Télécharger Imprimer la page

Hillyard SENTRY 141M Manuel D'utilisation Et D'entretien page 16

Publicité

1. PREPARING TO WORK
Before fitting the tanks, it is necessary to carry out certain operations:
1. Open the two rear hinges of the battery compartment.
2. Connect the connector to the batteries.
3. Close the battery compartment.
4. Make sure that the recovery tank is empty.
5. Position the recovery tank on the handlebars, and connect the two tubes.
6. Position the solution tank and connect the quick connector.
7. Carry out the operations to prepare the machine.
8. Lower the squeegee command lever in order to start working.
5. Press the main switch (1) and verify that the green indicator light comes on.
6. Press the suction switch (2).
7. Press the solenoid valve switch (3).
At this point - by using the operating lever that activates the brushes (4) - the machine can work efficiently
until the detergent solution runs out or the batteries run flat
2. OVERFLOW DEVICE
The machine is fitted with a ball filter which is activated when the recovery tank is full, causing the suction
tube to close.
In this case, it is necessary to switch off the machine and empty the recovery tank.
ATTENTION: This operation must be carried out wearing gloves to protect against
contact with dangerous solutions.
WORK
ENG - pag. 16
4
1
3
2

Publicité