Télécharger Imprimer la page

Kratki LUCY PW Instructions De Montage page 20

Publicité

EN
2. Screw off the hexagonal screw and pull out the valve conical head.
3. Clean all elements of the thermostatic valve, in particular the valve seat, with the stream of running
water.
4. Put together the thermostatic valve and finally screw on quite tightly the hexagonal screw.
Condensation
Condensation inside the firebox is as a result of improper operation of your stove.
The effect of this can be:
- Condensation forming on the inner walls of the firebox/stove and in extreme cases leakage out of
the unit,
- Smoke exiting the stove back in to the room,
- Dirty Glass and dirty combustion chamber,
- Loss of Damper control due to sticking.
In order to avoid the above, we would recommend using the guidelines as set out below:
- Set temperature to between 70 and 75
- Set the circulation pump thermostat to 55
Setting the thermostat at this level will allow the installation to heat up faster.
The water temperature difference between the desired working temperature, and the return water
temperature should not differ by more than 20
less than 50
C. That the wood moisture content is no more than 20%. This is related to the dew point
o
temperature (release of water vapour from the timber) of 48
The preferred fuel is seasoned wood e.g. beech, birch with a moisture content of no more than 20%.
Regular cleaning of the combustion chamber/Firebox and exhaust duct is recommended, especially
if there is a noticeable carbon build up.
11. AQUARIO insert
Construction diagram of a fireplace insert with the water system. Drawing 3.
The main part of the fireplace insert with a water system is the steel water jacket (16) located above
the combustion chamber (1). The steel door (2) equipped with a uniform heatproof glass (3) and a
closing lock with a handle (4) constitutes the front wall of the combustion chamber (1).
The door is mounted in the frame (5). The combustion chamber (1) is inlaid with Acumotte forms
(27). The double-jacket floor whose construction also constitutes the air supply chamber (6) serves
as the base of the system. Air supply is performed by means of the outdoor air supply stub pipe with
the The lower vermiculite deflector (26) is located above the combustion chamber. The upper steel
deflector (25) is located above it. The vertical water heater fire tubes (17) are welded onto the upper
inside walls of the water heater (18). The steel deflector (25) and the vertical water heater fire tubes
constitute the natural convection channel for fume flow, intensifying heat exchange. During the
burning process inside the insert, fumes wash the combustion chamber (1) walls, then pass under the
lower and upper deflectors and flow through the vertical fire tubes (17) and then sweep the water
heater (18), intensively transmitting heat to the water. Next, they flow to the flue (10) and through the
smoke channel leading to the chimney.
An adjustable damper (11) is installed in the flue. The position of the damper is adjusted by means
of the damper mechanism (12). Pulling the damper mechanism out by means of the damper handle
(13) is equivalent to opening the fume outlet cover (11). The lower damper (14) is an integral part of
the insert. It is located directly above the combustion chamber (1) and it constitutes an extension
of the upper steel deflector (25) along its entire length. Opening it in the preliminary phase of the
20
C,
o
C.
o
C and also that the return water temperature be not
o
C. Proper combustion of fuel is essential.
o

Publicité

loading

Ce manuel est également adapté pour:

Lucy/pw/12/wLucy/pw/16/wMba pw/17/gMbm pw 10 p/bs/wZosia pw 14 kwMbz pw 13 p/bs/w ... Afficher tout