11. m Electrical Connection
The electrical motor installed is connected and ready for operation. The connection complies with the applicable VDE
and DIN provisions. The customer's mains connection as well as the extension cable used must also comply with these
regulations.
Check electrical connection cables regularly for damage. Ensure that the connecting cable is not attached to the mains
when you are checking it.
Electrical connecting cables must correspond to the relevant VDE and DIN regulations. Only use connecting cables with
the code H 07 RN.
The type designation must be printed on the connecting cable by regulation.
Faulty electrical connecting cables
Insulation damage often occurs at electrical connecting cables.
Causes include:
• Pinch points when connecting cables are run through window or door gaps.
• Kinks resulting from incorrect attachment or laying of the connection cable.
• Cuts resulting from running over the connecting cable.
• Insulation damage resulting from forcefully pulling out of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables must not be used as the insulation damage makes them extremely hazard-
ous.
Three-phase motor 400 V/ 50 Hz
Mains voltage 400 Volt / 50 Hz.
Mains voltage and extension cables must be 5-lead = 3 P + N + SL. - (3/N/PE).
Extension cables must have a minimum cross-section of 1.5 mm² (≤ 25m).
Extension cables must have a minimum cross-section of 2.5 mm² (> 25m).
The mains connection is protected with a 16 A slow-blow fuse. The RCD breaker must have a 30 mA trip rating.