W-200 INTEGRA_ PRESSURE and SUCTION SPRAY GUNS
GB
3.1 TECHNICAL DATA
VERSIONS
W-200 INTEGRA serie 2 SP -
W-200SP-08WB1P
W-200SP-10WB1P
W-200SP-12WB1P
W-200SP-14WB1P
W-200SP-08WBSP
W-200SP-10WBSP
W-200SP-12WBSP
W-200SP-14WBSP
W-200 INTEGRA serie 2 FT with FLAT NOZZLE
W-200FT-08LV2P
W-200FT-10LV2P
W-200FT-12LV2P
W-200FT-15LV2P
W-200FT-16LV2P
W-200FT-18LV2P
W-200FT-08G2P
W-200FT-10G2P
W-200FT-12G2P
W-200 INTEGRA serie 2 SP - Water based version with SPLIT NOZZLE
W-200-SP-16WB2S
W-200-SP-18WB2S
W-200 INTEGRA serie 2 FT with FLAT NOZZLE
W-200-FT-14S
W-200-FT-15S
W-200-FT-18S
W-200-FT-20S
W-200-FT-25S
4. SAFETY WARNING
FIRE AND EXPLOSION HAZARDS
WARNING
SPARKS AND OPEN FLAMES ARE STRICTLY PROHIBITED
Paints can be highly flammable and can cause fire.
Do not expose to open flames, electrical goods, cigarettes etc.
SECURELY GROUND SPRAY GUN BY USING A CONDUCTIVE AIR HOSE.
ELECTRICAL RESISTENCE: <1MΩ. ALWAYS ensure that the spray gun is
earthed correctly. Insufficient grounding can cause fire and explosion due
to static electric sparking.
NEVER USE THE FOLLOWING HALOGENATED HYDROCARBON
SOLVENTS which can cause cracks or dissolution on gun body (aluminium)
by chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichlo-
romethane, 1.2-dichloroethane, carbon tetrachloride,
1.1.1-trichloroethane.
BE SURE THAT ALL FLUIDS AND SOLVENTS ARE COMPATIBLE WITH
GUN PARTS.
PROTECTION OF HUMAN BODY
WARNING
USE IN A WELL-VENTILATED SITE BY USING A SPRAY BOOTH.
If not, poor ventilation can cause organic solvent poisoning and catch fire. If you
feel any abnormality during operation, consult a medical doctor immediately.
AIR
NOZZLE
CAP
ORIFICE
MARK
mm (in)
Water based version with SPLIT NOZZLE
0.8 (0.031)
1.0 (0.039)
WB1
1.2 (0.047)
1.4 (0.055)
0.8 (0.031)
1.0 (0.039)
WBS
1.2 (0.047)
1.4 (0.055)
0.8 (0.031)
1.0 (0.039)
1.2 (0.047)
LV2
1.5 (0.059)
1.6 (0.062)
1.8 (0.071)
0.8 (0.031)
1.0 (0.039)
G2P
1.2 (0.047)
1.6 (0.062)
WB2
1.8 (0.071)
1.4 (0.055)
LV2
1.5 (0.059)
K2
1.8 (0.071)
2.0 (0.079)
R2
2.5 (0.098)
W1
AIR
FLUID
PRESSURE at
OUTPUT
Gun Inlet
ml/min
bar range
200
250
2.0 ~ 2.5
300
350
200
250
2.0 ~ 2.5
300
350
70
110
150
2.0 ~ 2.5
250
300
400
3.0 ~ 3.5
500
170
2.0 ~ 2.5
200
240
240
2.0 ~ 2.5
290
350
440
SPRAY DISTANCE: 150 ~ 300 mm
AIR
PATTERN
CONSUMPTION
WIDTH
l/min range
mm (in)
360 (14.2)
425 ~ 531
380 (15.0)
390 (15.4)
310 (12.2)
320 (12.6)
463 ~ 578
330 (13.0)
340 (13.4)
140 (5.5)
170 (6.7)
220 (8.7)
240 ~ 300
270 (10.6)
280 (11.0)
290 (11.4)
500 ~ 583
400 (15.7)
315 (12.4)
480 ~ 538
330 (13.0)
240 ~ 300
260 (10.2)
290 (11.4)
220 ~ 275
340 (13.4)
290 (11.4)
240 ~ 300
280 (11.0)
trichloroethylene,
4