SHUTDOWN
1. Remove all load by turning off electrical appliances and unplugging
electric cords.
2. Allow engine to run at idle speed (3000), or at no load condition (3000-
1MH0, 4000, 5000) to cool for two (2) minutes.
NOTE: Failure to allow the engine to cool for two (2) minutes may
result in damage to the generator.
3. Turn engine key or ignition switch off.
4. Close fuel valve on unit or engine.
CONTROLS
CONTROL PANEL:
The generators are equipped with the following items:
3000 w units:
- Circuit Breaker
- One 125 Volt, 20 Amp, GFCI protected receptacles.
4000 w and 5000 w units:
- Full Power Switch
- Circuit Breakers
- Two 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected recep-
tacles.
- One 125 Volt, 30 Amp, Locking Type Receptacle.
- One 125/250 Volt, 20 Amp, Locking Type Receptacle.
NOTE: The 125 Volt, 30 Amp locking receptacles ARE NOT
GROUND FAULT PROTECTED. If ground fault protection on
these receptacles is necessary or desired, external protection
devices must be used. Refer to the section on "Ground Fault
Interrupter" for more information.
WARNING: NEVER EXCEED THE RATING OF A RECEPTACLE.
THESE
RECEPTACLES
OVERLOADS BY RESETTING MAGNETIC TYPE CIRCUIT
BREAKERS. IF A CIRCUIT BREAKER TRIPS, THE CAUSE
SHOULD BE DETERMINED AND CORRECTED PRIOR TO
CONTINUING USE.
OIL WARNING DEVICE:
NOTE: This engine is equipped with a "Low Oil" shutdown system
for engine protection. The engine stops when the oil level gets
too low. The engine will not restart without adding oil. If the unit
is tilted too much during operation, it may suddenly stop even
though the oil level is not low.
Check the engine oil before restarting the engine. If the unit is tilted,
level the engine, then check the oil before restarting the engine.
FULL POWER SWITCH:
The Full Power Switch allows the unit to suppy power directly to the
120V-30A receptacle on the unit. This will disable all other receptacles.
When the Full Power Switch is in the 120V/240V position, all receptacles
are usable except the 120V-30A receptacle.
Do not use switch to add/remove load.
Operator's Manual
OPERATING THE GENERATOR
ARE
PROTECTED
AGAINST
19