Télécharger Imprimer la page

Mi-T-M Corporation GEN-3000-1MK0 Manuel D'utilisation page 16

Publicité

TEMPERATURE CHART
(Fig. 1)
UPPER LEVEL
(Fig. 2)
Operator's Manual
PREPARING THE GENERATOR
OIL GAUGE
ENGINE OIL
Use oil viscosity based on the expected air temperature range dur-
ing the period between oil changes.
Use a high quality detergent oil with API classifications of SJ or
higher.
Check oil level before each operation and ensure that it is main-
tained.
CAUTION: THIS ENGINE CRANKCASE IS NOT FILLED WITH
OIL AT THE FACTORY, SO BE SURE TO FILL IT BEFORE
OPERATING THE ENGINE.
ENGINE OIL CAPACITY
NOTE: These engines are equipped with a "Low Oil" shut-off
system for engine protection. If the engine fails to start,
check engine crankcase for oil.
To fill with oil:
MODEL #
GEN-3000-0MH0
GEN-3000-1MK0
GEN-3000-1LK0
GEN-3000-1MH0
GEN-4000-0MS0
GEN-4000-0MH0
GEN-5000-0MS0
GEN-5000-0MK0
GEN-5000-0MH0
1. Level the engine to ensure accurate inspection and to prevent
overfilling.
2. Unscrew the oil gauge (Fig. 1), wipe the dipstick dry. Reinsert the
oil gauge back into the oil fill gauge opening. Remove the oil gauge
and check the oil level.
3. The oil level should be between the full and low marks on the
dipstick. (Fig. 2)
NOTE: When checking the oil be sure the engine is level.
4. Fill with oil as required through the oil fill gauge opening.
5. Replace the oil gauge and screw in firmly.
6. Wipe up any spilled oil.
FUELING
WARNING: EXPLOSIVE FUEL! GASOLINE IS EXTREMELY
FLAMMABLE AND ITS VAPORS CAN EXPLODE IF
IGNITED.
STORE GASOLINE ONLY IN APPROVED CONTAINERS,
IN WELL VENTILATED, UNOCCUPIED BUILDINGS AND
AWAY FROM SPARKS OR FLAMES.
DO NOT FILL THE FUEL TANK WHILE THE ENGINE
IS HOT OR RUNNING, SINCE SPILLED FUEL COULD
IGNITE IF IT COMES IN CONTACT WITH HOT PARTS OR
SPARKS FROM IGNITION. DO NOT START THE ENGINE
NEAR SPILLED FUEL.
NEVER USE GASOLINE AS A CLEANING AGENT.
16
Liters
Quart
Ounces
0.6
0.61
20.3
0.6
0.63
20.3
0.6
0.63
20.3
0.6
0.61
20.3
0.6
0.63
20.3
1.1
1.16
37.2
1.0
1.06
33.8
1.3
1.4
44.8
1.1
1.16
37.2