Operator's Manual
OPERATION
RECOIL START
NOTE: Read Operator's Manual carefully before operating this unit.
Always make sure the unit is level and properly grounded. Check
engine oil before starting.
1. Open fuel valve on unit or engine. (See Fig. 3)
2. Move choke lever to full choke. If re-starting a warm engine, the choke
should be left in the off position. (See Fig. 4)
3. Turn the engine ignition switch to the ON position.
4. Pull recoil to start engine.
5. Once engine has started, slowly move choke lever to no choke.
NOTE: When engine fails to start after several attempts, repeat the
starting procedures mentioned above with the choke lever in the
off position.
6. Allow the unit to run for two (2) minute warm-up.
7. Make sure the generator is grounded. See Preparing the Generator;
Grounding Instructions.
8. Test the GFCI receptacle(s) on the unit. Push the test button. The reset
button should pop out and there should be no power at the receptacle.
Apply a test load or lamp to each receptacle to verify. IF THE RESET
BUTTON DOES NOT POP OUT, DO NOT USE THE RECEPTACLES(S).
SEE DEALER FOR SERVICE IMMEDIATELY.
9. If GFCI receptacle(s) test correctly, firmly push the reset
button to restore power. A distinctive click should be
heard or felt when this is complete. IF THE RECEPTACLE(S) DO NOT
RESET PROPERLY, DO NOT USE THE RECEPTACLE(S). SEE DEALER
FOR SERVICE IMMEDIATELY.
10. Loads can now be applied to the unit.
11. If unit is equipped with a Full Power Switch, move the Full Power Switch
to the 120V position to direct all power to the 120V/30A receptacle on
the unit (See Fig. 5). Thiswill disable all other receptacles.
When the Full Power Switch is in the 120V/240V position, all receptacles
are usable except the 120V/30A receptacle.
CAUTION: ENSURE ALL BREAKERS ARE IN THE OFF POSITION
BEFORE MOVING THE FULL POWER SWITCH.
NOTE: This engine is equipped with a "Low Oil" shutdown system
for engine protection. The engine stops when the oil level gets
too low. The engine will not restart without adding oil. Refer to
Preparing the Generator; Engine Fuel Capacity for instructions
on adding oil.
18