User manual - English
Ice cubes stick to
each other during
the ice-making
process
Machine runs, but
does not produce
ice
Ice cube maker
not running
despite power
plug switched on /
safety switch
('Pressostat') has
triggered
Tub is overfilled
with water / water
overflowing
User-manual-BlueLine-v.02
1. Ice thickness
motor switches too
late
2. Leak(s) in the
cooling system (ice
maker has
insufficient
refrigerant)
1. Leak(s) in the
cooling system
2. Compressor
faulty
3. Hot gas valve
faulty (valve no
longer closes)
1. Condenser is
soiled
2. In water-cooled
machines, the water
supply may be
interrupted
3. In water-cooled
machines, the
condenser or
cooling water
controller scaled
(lime).
4. Insufficient air
circulation for air-
cooled machines
5. Fan no longer
running
1. Water inlet valve
does not close
2. Probe cable(s)
interrupted
3. Fault in water
sensor electronics
1. Readjust ice thickness
motor(see also capitel 6.3)
2. Locate leak(s), rectify and
top up refrigerant
1. Locate and rectify leak(s) in
the cooling system
2. Replace compressor
3. Replace hot gas valve
1. Clean condenser
2. Open water supply
3. Descale condenser or
cooling water controller, or
replace if necessary
4. Check distances of the
machine to the side walls and
the rear, ensure ventilation
according to the specification
5. Replace fan motor
1. Replace water inlet valve
2. Measure electrical
conductance of the individual
cables, rectify interruption,
replace probe if necessary
3. Replace water sensor
electronics
01/2021
69