b. Air-cooled, built-in units (version LE)
1.
Switch off the machine at the production switch
(Position "Produktion aus/off").
2.
Lift the air-inlet grille on the side and remove towards
the front. The air intake duct is now accessible, and the
condenser fins can be cleaned.
3.
Loosen dirt particles, dust and fluff using a brush with
coarse bristles (not a metal brush!) and remove using a
vacuum cleaner.
4.
Remove the filter fleece from the air intake grille and
brush thoroughly. In case of strong contamination, e.g.
grease deposits, wash out the filter fleece in warm water
with fat-dissolving rinsing solution and dry prior to
reinstallation.
Insert the air intake grille and start up the machine (Position "Produktion ein/on").
5.
ADVICE:
If the condenser fins are heavily soiled, the machine must be removed. Switch off the
production switch (Position "Produktion aus/off"), pull out the machine towards the
front, pull the power plug and clean the fins with compressed air. Then follow the
cleaning instructions as described above.
!
CAUTION
When the device is pushed in, it may happen that the drain hose rises or kinks,
thereby preventing water drainage. Please note when reinstalling!
If you have any further questions about cleaning, please contact your specialist dealer or the
WESSAMAT service.