8. Installation
a) Inserting/Replacing the battery
1. Use a Phillips screwdriver to loosen the screw from the battery compartment lid (1) and
remove the lid.
2. Connect a 9 V block battery to the corresponding connection inside the battery compart-
ment. Only one orientation is possible. Do not use force.
3. Store the battery and the cable inside the battery compartment.
4. Close the battery compartment. Make sure that the cable is not pinched.
Replace the battery when BAT appears on the display.
Remove the battery from the product if it is not used for a long period of time.
b) Attaching the case handle
On the sides of the case lock, there are two holes for attaching the case handle. There are two
inward-pointing pegs on the case handle. Proceed as follows to attach the handle:
1. Insert one peg into one of the holes.
2. Carefully stretch the handle and then insert the second peg into the other hole.
3. To remove the handle, proceed in reverse order.
9. Preparations for measurement
Non-contact measurement
1
Measurements are conducted using reflection. The included self-adhesive reflective strips can
be fastened to rotating objects. The reflective strips then reflect the laser beam (4) emitted by the
device. A photodiode inside the device registers and analyzes the reflected laser beam. Make
the following preparations:
Cut off a square piece of the reflective strip (approx. 12 x 12 mm).
Fasten this piece to the test object. Make sure that the surface is dry and free from dust
and grease.
Before attaching the reflective strip, rotating components must come to a complete
stop and prevent them from being switched back on.