Replacing the cartridge
1.
Shut off the water supply to the faucet.
2. Turn on the faucet briefly to relieve any pressure inside the faucet.
3. Move the faucet handle to the "OFF" position.
4. Remove the set screw from the Handle Assembly (A) using a 2.5 mm Hex Key.
5. Pull the Lever Handle (A) from faucet body.
6. Unscrew the Cartridge Cap (B) from faucet body.
7.
Unscrew the Cartridge Lock Nut (C).
8. Lift Ceramic Disc Cartridge (D) from the body and replace it with a new one. Ensure
the two lugs on bottom of the cartridge sit properly in the allocated holes
at the base of the body.
9. Re-assemble faucet in reverse order.
10. Test for leakage.
20 mm