Télécharger Imprimer la page

Craftsman 139.18571D Manuel Du Propriétaire page 17

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum height of
5 feet (1.52 m) where small children cannot reach, away from
moving parts of door and door hardware. If installing into
drywall, drill 5/32" holes and use the anchors provided. For pre-
wired installations (as in new home construction), it may be
mounted to a single gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of bell wire
and connect to the two screw terminals on back of door
control by color: white wire to 2 and white/red wire to the 1.
2. Remove cover by gently prying at slot in side of the cover with
a small flat head screwdriver. Fasten with 6ABx1-1/4" self-
tapping screws (drywall installation) or 6-32x1" machine
screws (into gang box) as follows:
• Drill and install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of door control on screw head and slide
down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking plastic
housing. Do not over tighten.
• Insert top tabs and snap on cover.
3. (Standard installation only) Run bell wire up wall and across
ceiling to motor unit. Use insulated staples to secure wire in
several places. Do not pierce wire with a staple, creating a
short or open circuit. If your access door is near the garage
door, you may run this wire with the Safety Reversing Sensor
wires along the top of the rail. See page 17.
4. Insert all wires through the opening on top of motor unit
above the terminal block on the back panel (Figure 3).
5. Strip 7/16" (11 mm) of insulation from each set of wires.
Insert door control wire into quick-connect terminals by color:
white wire to white, white/red wire to red.
Separate white and white/black wires sufficiently to connect to
the opener quick-connect terminals. Twist like colored wires
together. Insert wires into quick-connect holes: white to white
and white/black to grey.
NOTE: When connecting multiple door controls to the opener,
twist same color wires together. Insert wires into quick-connect
holes: white to white and red/white to red.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual release/
safety reverse test label in a prominent location on inside of
garage door.
NOTE: DO NOT connect the power and operate the opener at this
time. The trolley will travel to the full open position but will not
return to the close position until the sensor beam is connected
and properly aligned.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white; white/red to
red.
Screw 6ABx1-1/4"
Control Panel (std installation)
Screw 6-32x1"
Control Panel (pre-wired)
Figure 1
REMOVE & REPLACE COVER
To Replace,
Insert Top
Tabs First
Figure 3
CONTROL
Push Bar
CONSOLE
Lighted
Push
Button
Top
Mounting
Hole
WHITE
Terminal
2
Screws
RED
Bell
Bottom
1
Wire
Mounting
Hole
(BACK VIEW)
17
HARDWARE SHOWN ACTUAL SIZE
Drywall Anchors
Figure 2
PRE-WIRED
INSTALLATION
To Remove,
Twist
Here
2-Conductor
Bell Wire
W
Light
Lock
BACK
Lock
9
Light
7
5
KG
To release or insert wire,
Door Control
push in tab with screwdriver
Connections
tip
Red
Strip wire 7/16"
(11 mm)
7/16" (11 mm)
White
Insulated
Staples
24 Volt
2-Conductor
Bell Wire
Quick-Connect
Terminals
9
1
1
7
3
3
5
KG
Antenna
Grey

Publicité

loading