After having carried out all connections, by carefully following the layout and having positioned
the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7, DL8, DL9 and
DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the following
and replace any faulty components.
DL6
OFF
Stop button malfunction (if Stop is not connected, perform the jump
between COM A+ and STOP).
DL7 or DL8
OFF
Faulty photocells (In case the edge is not connected, carry out jumper
between COM A+ and PHOTO 1/PHOTO 2)
DL9 or DL10
OFF
Faulty safety edge (In case the edge is not connected, carry out jumper
between COM A+ and EDGE 1/EDGE 2)
DL13 blue
ON
Some functions are enabled via smartphone, so via smartphone check
the card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and
insert them one at a time in order to more easily identify the cause of the fault.
EVENT
DIP 1 ON (hold-to-run mode)
Or failure of a safety device
DIP 2 ON (full stroke programming)
DIP 2 ON > DIP 1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety device
EVENT
No transmitter code entered
DIP 1 ON > DIP 2 ON - transmitter code programming for full opening
DIP 1 ON > DIP 3 ON - transmitter code programming for pedestrian opening
DIP 1 ON > DIP 2 ON > DIP 3 ON - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm from Self-learning failed
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
10 s tone with 2 s pause
BUZZER STATUS
1 Tone
1 Tone
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
1 Tone
2 Tones
2 Tones every 5 s for 1 minute
(It is renewed by giving a command)
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
6 Tones every 5 s
(It is renewed by giving a command)
Continuous tone for 10 s with 2 s pause.
Not active when DIP 2 in OFF
37
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
Flashes for 1 minute
OFF
OFF
OFF
OFF
OFF
OFF
OFF
DL1 LED STATUS
Flashes ON/OFF 250 ms
Flashes ON/OFF 500 ms
Flashes ON/OFF 500 ms
On steady
DL12 LED STATUS
Flashes red/green
Flashes red for 10 s
Flashes green for 10 s
Flashes orange for 10 s
Turns green once
Turns red once
Turns red once
Runs 6 green flashes
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
Led DL6 turns OFF
Led DL7-8 turns OFF
Led DL9-10 turns OFF
Led DL1 flashes ON/OFF 250 ms
No led combined
No led combined
Led DL12 is steady on green.
No leds matched
Blue led flashes once every 5 s
No leds matched
G
B

Publicité

loading

Ce manuel est également adapté pour:

Super 4000Super 4000 fcmSuper 4000 fce iceSuper 4000 fce sqSuper 4000 fce ice sqAa31030 ... Afficher tout