Télécharger Imprimer la page

GYS POT PTI GENIUS Mode D'emploi page 49

Masquer les pouces Voir aussi pour POT PTI GENIUS:

Publicité

Les langues disponibles

Les langues disponibles

GLUE mode:
On the SETTINGS screen below, the user can specify the presence glue between the panels/sheets. When this mode is in use, a pre-spot is performed
before the weld. The duration of this pre-spot is set in milliseconds, from 0 to 400 ms, with 50 ms thresholds. When the glue mode is selected, la
word « GLUE » is displayed in the menus of the NORMAL, MANUAL, MULTI or GYSTEEL welding modes.
ERROR MANAGEMENT
Low battery
Invalid tool
Invalid arm
Current too low
BMW C7502655 - GYSPOT PTI GENIUS
Various elements may produce errors. They can be split into 4 categories :
1/ Warning messages designed to warn the operator of overheating, lack of pressure or power, etc.
These messages are displayed on the screen and remain visible until a button is pressed.
2/ The faults that occur in relation to insufficient air pressure or power supply.
3/ The serious faults that block the machine. In this case, contact the service department
4/ The thermal protection is linked by a thermistance on the diode bridge and when it activates the
machine is locked and the message «overheating» is displayed.
The message «Battery low» is displayed when the machine is switched on and it indicates that the
battery on the command board is low. This battery is used to record the date and time when the
machine is switched off.
The message «Invalid tool» is displayed when the machine is switched on and indicates that a button
is pushed in, the trigger is pushed in or a permanent short-circuit. Check the trigger or the buttons on
the clamps to remove the message.
The arm used is not compatible with the welding mode selected.
1/ Check the weld
If the current obtained during a spot weld is lower than the expected value (6%), the machine dis-
plays the warning message «Low current, check the weld».
2/ Check the sheets
If the machine cannot deliver the current required, the error message «Low current, check the
sheets» is displayed. The weld does not happen and the fault must be skipped for the weld to happen.
EN
49

Publicité

loading

Ce manuel est également adapté pour:

Bmw c7502655