Technical Data - EINHELL BG-AW 1136 Mode D'emploi D'origine

Système automatique d'eau à emploi domestique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Anleitung_BG_AW_1136_SPK7__ 08.08.12 11:20 Seite 10
GB
3. Items supplied
Open the packaging and take out the equipment
n
with care.
Remove the packaging material and any
n
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
n
Inspect the equipment and accessories for
n
transport damage.
If possible, please keep the packaging until the
n
end of the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
Original operating instructions
n
4. Proper use
Applications
Irrigation and watering of green areas, vegetable
n
beds and gardens.
Operation of lawn sprinklers.
n
For drawing water from ponds, streams,
n
rainwater butts, rainwater cisterns and springs
For supplying service water
n
Transport media:
For the pumping of clear water (fresh water),
n
rainwater or light suds/service water.
The maximum temperature of the fluid must not
n
exceed +35°C if the equipment is operated
permanently.
Do not use the equipment to pump inflammable,
n
gassing or explosive fluids.
The pumping of aggressive liquids (acids,
n
alkalis, silo seepage etc.) as well as liquids with
abrasive substances (sand) must likewise be
avoided.
This equipment is not designed to convey
n
drinking water.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
10
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

5. Technical data

Mains supply:
Power rating:
Delivery rate max.
Delivery height max.
Delivery pressure max.
Suction height max.
Delivery and intake connection:
Water temperature max.
Protection type
6. Electrical connections
Connect the power cable to a 230 V ~ 50 Hz
n
earthed, 10 amp fuse minimum.
The appliance is switched on and off using the
n
integrated ON/OFF switch.
The motor is protected against overloading or
n
blocking by an integrated thermostat. In the event
of overheating, the thermostat switches off the
pump automatically. The pump will start up again
automatically after it has cooled down.
7. Fitting a suction pipe
Screw an intake hose (min. 19 mm (3/4" ) plastic
n
hose with spiral reinforcement) either directly or
with a threaded nipple to the pumpʼs intake
connection (33,3 mm (R1)) (see Fig. 1).
The intake hose should rise from the water pick-
n
up point to the pump. Always avoid laying the
intake line higher than the pump. Air bubbles in
the intake line delay and hinder suction.
The intake and pressure lines must be attached in
n
such a way that they do not place the pump under
any mechanical strain.
The intake valve should be so far immersed in the
n
water that the pump cannot run dry even if the
water level falls.
If the intake line is not air-tight, the intake of air
n
will hinder the intake of water.
230V ~ 50 Hz
1100 W
3600 l/h
46 m
0,46 MPa (4,6 bar)
7 m
33,3 mm (R1 IG)
35°C
IP44

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.767.1211021

Table des Matières