Troubleshooting Guide - EINHELL BG-AW 1136 Mode D'emploi D'origine

Système automatique d'eau à emploi domestique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Anleitung_BG_AW_1136_SPK7__ 08.08.12 11:20 Seite 13

15. Troubleshooting guide

Faults
Motor fails to start up
No intake
Inadequate delivery rate
Thermostat switches pump off
Cause
- No mains voltage
- Pump rotor blocked -thermostat
switched off
- Intake valve not in water
- Pump chamber without water
connection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Suction height too high
- Coarse filter dirty
- Water level falling rapidly
- Pump performance
diminishedby contaminants part
- Motor overloaded - friction
caused by foreign substances
too high
GB
Remedy
- Check voltage
- Dismantle and clean pump
- clean
- Remove the coarse filter with the
non-return valve, then fill water
into the pump housing.
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
- Check suction height
- clean
- Place the suction hose at a
deeper level
- Clean pump and replace
wearing
- Dismantle and clean pump.
Prevent intake of foreign
substances (filter)
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.767.1211021

Table des Matières